Installation Guide
6
1/2021
© 2021 Monte Carlo Fan Collections
6
REMOTE CONTROL SETTING and OPERATION
Universal Mode and Learning Mode
There are “Universal Mode” and “Learning Mode” with the remote controller. 
If choosing “Universal Mode”, simply place dip (code) switch at UPPER 
position. Your fan with the remote controller is ready to use. 
Note: If using universal mode, your fan can be controlled with other remote 
transmitters with the same setting.
To control the fan with specific remote transmitter, choose “Learning Mode” 
by placing the dip (code) switch at LOWER position and then make learn 
function setting as below. 
Learn function setting, Restore power source to your fan, press and hold 
the “LEARN” button for at least 3 seconds. You must press the “LEARN” 
button within 60 seconds of restoring power to the fan.
Note: If the power is on already, you must turn the power off for 10 seconds 
at least, and then turn the power back for remote control learn function 
setting. 
Note: If the fan is installed with light, light will twinkle 2 times. The remote 
control setting process is complete and your fan is ready for use. For fans 
without light, check operation using remote transmitter. 
Note: If you want to control the fan with another transmitter, make the same 
setting. A fan can be controlled by 2 transmitters maximum.
Transmitter Operation 
Remove the battery cover from the remote control transmitter and install 
battery, battery provided. Replace the cover.
Note: Use 2 1.5V/AAA  battery. 
Note: If not using for long period of time, remove battery to prevent damage 
to remote transmitter, and store the remote transmitter away from excess 
heat or humidity.
ON
DIM
LEARN
L.CODE
COMMON
CODE
L.CODE
COMMON
CODE
ON
DIM
Universal Mold 
Learning Mold
Dimming / Non Dimming Setting
The “DIM” selection is the light dimmable selection and the light will cycle 
from bright to dim to bright until button is released. The “ON” selection is the 
light ON/OFF only (non dimming function). Light will maintain last setting if 
turned off.
Note: The remote controller is set with dimming function at factory, 
Note: If the remote receiver has been wired with fan, turn power off by wall 
switch before switch “DIM” and “ON/OFF” selection. 
Dimming/
Non dimming
LEARN
Learn
The receiver provides the following protective functions
Lock protection- The DC motor has a build-in safety feature against blade or motor obstruction during operation. If 
something obstructs the fan blades or motor, the motor will keep trying to run for 5 times and then stop operation 
after about 60 seconds of interruption. Please remove obstacles and reset. To reset it by turn the fan off by remote 
transmitter and then turn the fan on, Or you may turn power off for 15 seconds then turn power back, and then turn 
the fan on, 
Over load protection (current limit)- The device will limits the maximum current output from the receiver/drive when the 
fan or light load was increased abnormally. 