Instructions / Assembly
4
© 2016 Monte Carlo Fan Company
2/25/2016
7 8 9
10 11 12
Place downrod over canopy, canopy ring 
and yoke cover. 
Thread lead wires and safety cable from 
motor assembly through downrod.
For easy installation of cross ping on next 
step. 
Carefully insert a phillips screwdriver through 
yoke and downrod (don’t damage the lead 
wires) as a guide and then push the cross 
pin and pull the screwdriver in the meantime 
as shown in illustration.
Slip downrod into motor yoke, aligning 
holes and install cross pin and keeper pin. 
Insert cross pin through yoke and downrod 
until point appears on the other side, and 
insert keeper pin on cross pin. 
Pull the downrod up tight against the 
cross pin, and then evenly tighten the 
downrod set screws on motor housing 
yoke. 
Place yoke cover on top housing of fan.
Warning: Cross pin and keeper pin must 
be installed securely, failure to install them 
will result in serious injury.
Install ball end of downrod into mounting 
bracket opening. Align (engage) slot on 
ball with tab on mounting bracket.
Warning: Failure to align slot on ball with 
tab may result in serious injury.
Important: If using the angle mount, 
make sure open end of mounting bracket 
is installed facing the higher point of the 
ceiling and make sure the ceiling angle is 
not steeper than 15º. 
Connect the safety cable from fan to the 
Ceiling support cable.
Slide cable clamp onto the safety cable 
from fan. Place the end of cable through 
the loop of ceiling support cable and then 
feed end of cable into clamp hole and 
firmly tighten set screw. Cut off excess 
safety cable.
Make sure that when the safety cable is 
fully extended the lead wires are longer 
than the cable and no stress is placed on 
the lead wires. 
Attach Safety
Cable to Ceiling
Support Cable
Tab
Safety cable from fan
Cable clamp
Set screw
Hanger ball
Cross pin
Screwdriver
Hanger Bracket
Se crew
S
Cross pin
Keeper pin
Canopy
Canopy ring
Yoke cover
Downrod