Flush Mount Installation
Install ball end of downrod into mounting 
bracket opening. Align (engage) slot on 
ball with tab on mounting bracket.
Warning: Failure to align slot on ball with 
tab may result in serious injury.
Important: If using the angle mount, 
make sure open end of mounting bracket 
is installed facing the higher point of the 
ceiling and make sure the ceiling angle is 
not steeper than 30º. 
For Canadian installation and for USA fan 
and light kit combinations over 35 lbs, in 
both flush and downrod modes the safety 
cable must be installed into the house 
structure beams using 3” lag screws, 
washers and lock washers provided. 
Make sure that when the safety cable is 
fully extended the lead wires are longer 
than the cable and no stress is placed on 
the lead wires.
Note: If Installing The Secondary Support 
Safety Cable in the U.S., Do Not Remove 
Knockouts In The Outlet Box.
Make wiring connections using wire 
connectors provided as indicated above. 
White from fan to White from remote 
marked N. Black from fan to Black from 
remote marked L. Blue from fan to Blue 
from remote marked FOR LIGHT. White 
from house to White from remote marked 
AC IN N. Black from house to Black from 
remote marked AC IN L. Connect all 
green grounded wires to Grounded wire 
from House. Make sure that no filaments 
are outside of the wire connectors.
Insert the remote receiver into mounting 
bracket. Refer to page 7 for receiver 
setting.
After making the wire connections, the wires 
should be spread apart with the grounded 
conductor and the equipment-grounding 
conductor on one side of the outlet box and 
ungrounded conductor on the other side of 
the outlet box. The splices after being made 
should be turned upward and pushed carefully 
up into the outlet box. 
Lift Canopy allowing the 2 studs to protrude 
through the canopy.
Next lift the cover ring and install knurled nuts 
as shown. Tighten the knurled nuts securely. 
The canopy should adjust for any irregularity 
in the ceiling or Outlet box.
Make sure the studs protruding from the 
bottom of the Mounting bracket are installed 
with threads all the way through the bracket. 
Remove every other screws from yoke 
located on top of fan assembly. Keep 
screws.
Note: Flush mount is not available with 
vaulted ceiling. 
Tab
Slot
Go to step 20 to finish 
installation
Stud
Wall switch
Black
(Live)
White
(Neutral)
Ground/Green
White
White
Black
Black
Blue
Receiver
Power source
SAFETY CABLE INSTALLATION
Lag screw
Safety cable
Washer
Lock washer
Grounded
wires
Ungrounded
wires
Receiver