Before you begin installing the fan, Switch 
power off at Service panel and lock 
service disconnecting means to prevent 
power from being switched on 
accidentally. When the service 
disconnecting means cannot be locked, 
securely fasten a warning device, such 
as a tag, to the service panel.
Before installing this fan make sure the 
outlet box is properly installed to the 
house structure. To reduce the risk of 
fire, electric shock, or personal injury, 
mount to outlet box or supporting system 
acceptable for fan support. 
(Mounting must support at least 35 lbs.)
Use metal outlet box suitable for fan 
support and use only the screws provided 
with the outlet box (must support 35 
lbs). Before attaching fan to outlet box, 
ensure the outlet box is securely fastened 
by at least two points to a structural 
ceiling member ( a loose box will cause 
the fan to wobble). Remove the two outlet 
box screws provided with the box, 
aligning the holes of the mounting plate 
with the holes of the outlet box. Reinstall 
the 2 outlet box screws securely.
Loosen 2 screws across from each other 
and remove the other 2 preassembled 
screws from mounting plate 
(Corresponding to installation step 8). 
Save screws for later use. 
Set dip switches on the Remote 
Transmitter and Remote Receiver to the 
same settings. This must be done so the 
units will communicate properly. If you 
have other fans you can set to control 
from one Transmitter by setting 
receivers the same as the Transmitter. If 
you have more than one fan with remote, 
you can set the dip switches to different 
positions to have separate control.
Note: Remote receiver is located on the 
top plate of motor assembly as shown in 
the graphic of installation step 7. 
Hang motor assembly onto the hook on 
mounting plate for hands-free wiring and 
safety cable installation.
For Canadian installation and for USA fan and 
light kit combinations over 35 lbs, in both 
flush and downrod modes the safety cable 
must be installed into the house structure 
beams using 3” lag screws, washers and lock 
washers provided. Make sure that when the 
safety cable is fully extended the lead wires 
are longer than the cable and no stress is 
placed on the lead wires.
Note: If Installing The Secondary Support 
Safety Cable in the U.S., Do Not Remove 
Knockouts In The Outlet Box.
ON
Dip switches
Hook
Lag
screw
Safety
cable
Washer
Lock washer
3