Instructions / Assembly
4
© 2013 Monte Carlo Fan Company
4/25/2013
7 8 9
10 11 12
Make wiring connections using wire 
connectors provided as indicated above. 
White from house to White from remote 
receiver marked AC N. Black from house 
to Black from remote marked AC L. 
Connect all green grounded wires to 
Grounded wire from House. Make sure 
that no filaments are outside of the wire 
connector.
Lift motor assembly, aligning the keyhole 
slots with the preassembled screws on 
mounting plate, and twist clockwise till 
lock. Reinstall the screws removed in 
step 4. Tighten all screws securely. 
Loosen 2 screws across from each other 
and remove the other 2 preassembled 
screws from side of mounting plate 
(corresponding to installation step 10). 
Save screws for later use. 
Attach housing onto mounting plate, 
aligning the keyhole slots on the housing 
with the screws on mounting plate and 
twist clockwise till tight. Reinstall the 
screw removed in step 9. Tighten all 
screws securely. 
Install blade with screws provided, 
aligning each of the holes as shown and 
tighten all screws securely. Repeat this 
process for remaining blades.
Loosen 2 and remove 1 preassembled 
screw from the plate on motor. Save 
screw for later use. 
Receiver
Capacitor
Driver
Ground/Green
White
Wall
switch
Black
Power
source
Housing
Blade
Plate on motor