Specifications

active, processor controlled, bi-amped speaker system
W24A
11
ENGLISH
Wiring of the power cable for the Power Con
®
connector (supplied with the unit):
Strip the cable for 20 mm of length and strip each wire for
8 mm of length. We suggest to use a power cable with
1,5 ÷ 2mm
2
section wires (the insert terminals can however
support a cable with wires up to a section of 4mm
2
/12AWG).
Insert the power cable into the bushing and into the chuck
(white chuck for a cable diameter of 5 ÷ 11mm; black chuck
for a cable diameter of 9.50 ÷ 15mm).
Fit a ferrule at the end of each wire and connect wires on
the insert
The wire ends can be clamped in the terminals using an Allen
wrench or soldered by always paying attention to the
symbols shown on the connector: L (Live - corresponding to
the brown wire), N (Neutral - corresponding to the light blue
wire) and (Ground - corresponding to the yellow and
green wire).
After connecting the wires to the insert, lead the cable
through the body and screw down the body with the
bushing.
Important !
SETSCREWS
N
L
INSIDE VIEW
INSERT
CABLE
WIRES
20 mm
8 mm
Power supply connection:
• Make sure that the mains voltage corresponds to
the voltage indicated on the rear panel, under the mains
socket.
POWER CON
®
CONNECTOR
HOUSING
BUSHINGCHUCK
CABLE
FERRULES
FOR
STRANDS
WIRES
• Use only the factory supplied mains cable or, if a different
plug style is needed, a suitable cable with
a ground connection and marked with the safety approvals
valid in the country of use.