Operating instructions

7
Electrical Connection
A terminal block is provided for 208-240 VAC equipment. The wiring diagram is located on the
back of the range. To connect supply wires, remove cover from connection box at right rear of
range. Route supply wires and ground wire through hole with strain relief fitting at top of connection
box. Attach supply wires to proper terminal of terminal block. Attach ground wire to ground loug in-
side connection box. See wiring diagram for proper connection.
THIS APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN
ACCORDANCE WITH LOCAL CODES. THIS APPLIANCE MUST BE INSTALLED WITH THE
REQUIREMENTS OF AS5601 / AG601, LOCAL AUTHORITY, GAS, ELECTRICITY, AND ANY
OTHER RELEVANT STATUTORY REGULATIONS.
THE ELECTRICAL CONNECTION IS LOCATED 254mm ABOVE THE FINISHED FLOOR AND
305mm FROM THE RIGHT SIDE ON THE REAR OF THE UNIT.
The installation of electrical wiring from the electric meter, main control box, or service outlet to the
electric appliance must be performed by a licensed electrician. Qualified installation personnel
must be experienced with such work, be familiar with all precautions required and have complied
with all requirements of state or local authorities having jurisdiction.
OVERALL DIMENSIONS (in millimetres):
Model Height Width Depth
E36W36 1816 914 933
E43W36 1816 1143 933
E(V)136W36 1816 914 933
E(V)136C36 1451 914 933
E(V)136C45 1451 1143 933
E136XC36(SHB) 1426 914 870
E136XC45(SHB) 1426 1143 870
E236W36 1603 914 870
E243W36 1603 1143 870
EC36(SHB) 1324 914 870
EC45(SHB) 1324 1143 870
EC36W36 1968 914 864
EC43W36 1968 1143 864