SAFETY AND PILOT BURNER INSPECTION
SAFETY PILOT VALVE
Model H15HR is an automatic 100% safety pilot
which provides complete gas shut off in event of pilot fail-
ure. The safety valve is held closed by spring pressure.
When red button is pushed by hand, gas flows to pilot. Pilot
heats thermocouple creating a very small amount of elec-
tricity. This energizes a magnetic coil under the red button
and holds valve open, permitting gas to flow to main burner
and pilot holding pressure on red button. In the event of pilot
failure, the flow of electricity will stop and spring will stop
flow of gas to both pilot and oven burner.
OVEN PILOT BURNER
PILOT SERVICE IN THE EVENT OF PILOT FLAME FAILURE
1. If pilot flame burns yellow, clean pilot orifice and pilot burner
to insure a steady blue flame. The P/N 010138 orifice can be
cleaned by Pilot Burner washing in a solvent and/or blowing
out with air.
2. Flame must surround the thermocouple tip for approximately
1/2 inch.
WHEN SERVICE IS NEEDED, CONTACT A LOCAL SERVICE COMPANY, DEALER,
OR FACTORY TO PERFORM MECHANICAL MAINTANACE AND REPAIRS. THESE
INSTRUCTIONS ARE INTENDED FOR USE BY COMPETENT SERVICE
PERSONNEL.
CAUTION: TURN OFF GAS SUPPLY WHEN SERVICING GAS CONTROL SYSTEM.
NORMAL NOT LESS THAN
15-25 8
CLOSED CIRCUIT MV RANGE
THERMOCOUPLE OUTPUT