Operating instructions

27
Perform the following procedures to remove
and replace parts. To eliminate mistakes when
ordering parts, always provide the following
information:
Model Number
Serial Number
These numbers are located on the nameplate.
CAUTION: Turn off the broiler gas valve and
allow broiler to cool before removing any
components.
THIS APPLIANCE, WHEN INSTALLED,
MUST BE ELECTRICALLY GROUNDED IN
ACCORDANCE WITH LOCAL CODES. THIS
APPLIANCE MUST BE INSTALLED WITH
THE REQUIREMENTS OF AS5601 / AG601,
LOCAL AUTHORITY, GAS, ELECTRICITY,
AND ANY OTHER RELEVANT STATUTORY
REGULATION.
COVERS AND PANELS
CAUTION: Turn off the gas supply at the
manual shutoff valve that is next to the
broiler before attempting to loosen any gas
connections.
Venturi Cover
Removal of the Venturi cover provides access
to the air shutter adjustments and main burner
orifices.
1. Remove the two screws under the front
edge of the Venturi cover.
2. Lift the Venturi cover from the broiler.
Figure 1. Venturi Cover
Control Panel Cover
Removal of the control panel cover provides
access to the burner valves, pilot adjustment
and carriage springs.
1. Turn the control valves to the full off posi-
tion, then remove the control valve knobs.
2. Remove the two screws from the front of
the control panel.
Figure 2. Control Panel Cover
PARTS REMOVAL AND REPLACEMENT PROCEDURES