Connecting the Liquid Propane Gas Cylinder
To connect the liquid propane gas cylinder:
1. The cylinder valve should be in the OFF position.
2. Make sure the burner valve is in the OFF position.
3. Inspect the valve connections, port and regulator assembly. Remove debris and inspect the
hose for damage.
4. When connecting the regulator assembly to the valve, use your hand to tighten the nut
clockwise until it stops. *the use of a wrench could damage the quick coupling nut and result in
a hazardous situation*
5. Open the cylinder valve fully by turning the valve counterclockwise.
6. Before lighting the grill, use a soap and water solution to check all connections for leaks.
7. If a leak is found, turn the cylinder valve OFF and do not use the grill until a local liquid propane
dealer can make repairs.
Disconnecting the Liquid Propane Gas Cylinder
To disconnect the liquid propane gas cylinder:
1. Turn the grill burner vale OFF and make sure the grill is cool.
2. Turn the liquid propane cylinder valve OFF by turning clockwise until it stops.
3. Detach the regulator assembly from the cylinder valve by turning the quick coupling nut
counterclockwise.
4. Place the dust cap for the cylinder valve outlet whenever the cylinder is not in use.
Leak Testing
General
Although the gas connections of the appliance are leak tested prior to packing and shipment, a
complete test must be performed at the installation site. Before each use, check all the gas connections
for leak testing using the procedure listed below. If the smell of gas is detected at any time, you should
immediately stop using and check the entire system for leaks.
Before Testing
Make sure all packaging has been removed from the appliance.
Make a solution of one part liquid detergent and one part water. You will need a spray bottle, brush or
rag to apply the solution to the fittings.
To Test
1. Turn the burner valve OFF
2. Turn the liquid propane cylinder valve off counterclockwise to open the valve.
3. Apply the soap solution to all gas fittings. Soap bubbles will appear where a leak is present.
4. If a leak is present, immediately turn the gas supply OFF and tighten leaky fittings.
5. Turn the gas back ON and recheck
6. Should the gas continue to leak from the any of the fittings, turn the gas supply OFF and
contact customer service.