Instruction manual
Follow these instructions to avoid overlling the Boiler.
• Be sure the appliance is unplugged from the power outlet.
• Carefully remove the Boiler Cap by
turning it counter-clockwise.
• Pour in a maximum of 800ml of water
using the Filler Funnel provided. Do not
overll the Boiler, excess water in the
Boiler will be ushed out of the unit,
resulting in wet surfaces when
cleaning. Dry steam will only emit
if the Boiler is not overlled.
• Replace the Boiler Cap by turning it
clockwise. Do not over-tighten the Boiler Cap,
nger tight is sufcient.
• Plug electrical cord into a 3-prong,
grounded power outlet.
• The Steam Cleaner will heat up, produce
steam and the Boiler will become pressurised.
• When the orange Power Indicator Light turns green, the Steam Cleaner
is ready to use.
Note: the green light will change back to orange when
steam is released, this is normal and not a fault. During use the light will
alternate between orange and green, this is also normal and not a fault.
• If using cold water, heating time is about 5-6 minutes. Using hot water will
reduce the heating time.
NOTE: Do not turn on Steam Cleaner if Boiler is empty.
*IMPORTANT*
Use ordinary tap water. Use distilled or demineralized water if tap water is too
hard. DO NOT add detergents, perfumes, oils or other chemical substances.
7
Before Use
Before Use
3
Filling Steam Cleaner with Water
WARNINGS
• Carefully read all instructions before removing Boiler Cap.
• ALWAYS vent the Boiler (release all pressure/steam) before opening
Boiler Cap. Venting is done by sliding the Steam Control Trigger
forward to the “On” position.
• Always unplug unit and be sure it has cooled off before filling or
re-filling the Boiler – at least 5 minutes.
• NEVER turn on Steam Cleaner if the Boiler is empty!
CAUTIONS
• Always drain condensed water from Hose before use or if appliance has
been left idle for a period of time. To drain, direct Nozzle into a sink and
slide Steam Control trigger on Steam Gun forward. Once Hose is empty,
resume normal use. Never direct Nozzle toward people, animals or plants.
• Extreme care should be taken when opening the Boiler Cap as it may
become hot during use and escaping steam can cause scalding.
Max. 800ml