Specifications

Design Information
PRODUCT DIMENSIONS
ZVC48
Dimensions and Specifications (in inches)
Outside Dimensions
I" 39-1/2"
© © ©
The custom canopy must be sized to fit the insert
sleeve. Construct the canopy with an opening
that is:
38-3/4"W x 13-3/16"D
The opening must be constructed of 3/4" thick
material to allow the sleeve locking clips to
engage.
The Supplied Liner
46-1/2"
21-1/4"
_/
The stainless steel liner is shipped with each hood
insert. This non-combustible liner protects the
underside of the canopy,
Custom Liner
If you ore not using the supplied liner, you moy
construct a custom non-combustible liner. Use the
supplied liner as a template. The opening must be
38-3/4"W x 13-3/16"D. 3/4" thick moterial must
surroundthe opening to allowthe sleevelocking
dipstoengage. The insertsleeveinsidethe cabinet
should be positioned112"from the rearwallso
thatthe centerofthe 8"duct is5-1/2"from the
reor wall.
The Insert Sleeve
29-1/2"
38-1
1/2"
A 1/2" wide flange surrounds the outside edge of
the insert sleeve.
Remote Location for the Control
The control may be removed from the hood
and installed into a wall or countertop. A 30-ft.
length of wire is supplied to accommodate most
installations. A blanking plate covers the opening
when the controls are removed.
The overall size of the control is 4-1/4" wide and
2-1/4" deep.
3-11/16"
1-11116"
Control cutout
We recommend thot the cutout in gronite or other
hard surfaces be made before the countertop is
installed.