I I S 30", 36" and 48" Custom Hood Insert ZVC3OLSS ZVC36LSS ZVC48LSS Monogram° 49-80415 I 12-06 JR
Installation Instructions BEFOREYOU BEGIN Read these instructions carefullg. completelg WARNING:ToREDUCE THE RIsK and A, • IMPORTANT- Save these instructions for local inspector's use. • IMPORTANT- B, Observe all governing codes and ordinances. • Note to Installer- Be sure to leave these instructions with the Consumen • Note to Consumer - Keepthese instructions for future reference. • Skill Level- Installation of this vent hood requires basic mechanical and electrical skills.
Installation AVERTISSEMENT :AFIN DE REDUIRELERISQUED'INCENDIE,DECHOCS ELECTRIQUES OU DE BLESSURES CORPORELLES, VEUILLEZVOUSCONFORMERAU× RECOMMANDATIONS SUIVANTES: A. L'installation et le c6blage doivent _tre faits par une ou des personnes qualifi6es et en conformit6 6 tousles codes et normes applicables,g compris les normes en mati@rede coupe-feu. B.
Design Information CONTENTS Design Information Product Clearances Product Dimensions Installation .......................................................................... 4 .................................................................... 5-7 Advance Planning Advance Planning ............................................................................ 8 Remote Mounting of the Control (Wired) .............................. 8 Power Supplg ................................................................
Design Information PRODUCT DIMENSIONS ZVC30 Dimensions and Specifications (in inches) Outside Dimensions 27-1/2_ The Insert Sleeve The custom canopg must be sized to fit the insert sleeve. Construct the canopg with an opening that is: 26"W x 13-3116"D The opening must be constructed of 3/4" thick material to allow the sleeve locking clips to engage.
Design Information PRODUCT DIMENSIONS ZVC36 Dimensions and Specifications (in inches) Outside Dimensions 27-1/2" The Insert Sleeve The custom canopg must be sized to fit the insert sleeve. Construct the canopg with an opening that is: 26"W x 13-3116"D 16-3/4" The opening must be constructed of 3/4" thick material to allow the sleeve locking clips to 14" engage.
Design Information PRODUCT DIMENSIONS ZVC48 Dimensions and Specifications (in inches) Outside Dimensions I" 39-1/2" © © © The Insert Sleeve The custom canopy must be sized to fit the insert sleeve. Construct the canopy with an opening that is: 38-3/4"W x 13-3/16"D 29-1/2" The opening must be constructed of 3/4" thick material to allow the sleeve locking clips to engage. The Supplied Liner 38-1 46-1/2" 1/2" 21-1/4" _/ The stainless steel liner is shipped with each hood insert.
Advance Planning ADVANCE PLANNING POWER SUPPLY Ductwork Planning • This hood is equipped for 8" round ductwork.
Advance Planning DUCT FITTINGS Use this chart to compute maximum permissible lengths for duct runs to outdoors. Duct Piece NOTE: Do not exceed maximum permissible equivalent lengths! Maximum duct length: 100 foot for 8" round duct (_ Dimensions Equivalent Length* Round, straight i ft. (per foot length) 3-1/4" x 12" 3-1/4" x 24" straight 1 ft. (per foot length) 90° elbow 8" round 17 ft. 45° elbow 8" round 10 ft. 3-:1/4" x 10" 14 ft. 3-1/4" x 12" 90° elbow 15 ft.
Installation Preparation TOOLS AND MATERIALS REQUIRED _ (NOT SUPPLIED) 1/4" pivoting soo et Needle-nose pliers __ Aluminized duct tape "_ _ Knife L Wire nuts S _ Safety glasses _;:_ _ Gloves J Electric drill and appropriate bits 3/8" socket/ nut driver Silicone Pencil and tape measure 1" conduit (for remote mounting only) 8" ducting and caps as needed 1 Step ladder Plumb line Phillips and flat blade screwdrivers Flashlight Wire cutter/stripper Strain relief REMOVE THE PACKAGING
Installation Preparation PARTS PROVIDED Locate the parts packed with the hood. CHECK INSTALLATION HARDWARE Hood liner (packed in separate carton) components. Screws shown actual size.
Wall Installation DUCTWORK, WIRING Preparation 5-1/2" from rear wall to centerline LOCATIONS Determine the exact location of the insert sleeve. Mark the exact centerline location. The ceiling structure must be capable of supporting the weight of the insert sleeve (appro×imatelg 100 pounds) and ang inadvertent user contact loads, l • Measure from the top of the cooking 16"above pencil surface to the bottom edge of the insert line indicating sleeve.
Island Installation Preparation CONSTRUCT CEILING SUPPORT (for Island Installation) Plan the Location of the Hood and Ductwork The ceiling structure must be capable of supporting the weight of the insert sleeve (approximatelu !00 pounds) and anu inadvertent user contact loads. The insert sleeve in the ceiling must be centered left to right over the cooktop, • Use a plumb bob to check the location, The countertop/cooktop below the insert sleeve must be centered with the insert sleeve.
Installation Preparation REMOTE MOUNTING OF THE CONTROL (WIRED} REMOTE LOCATION installed in a backsplash -- ILWARNING: Disconnect electrical d_brancher I'alimentation or countertop. • A cover plate is provided to cover the opening in the hood when the control is removed. power from unit before beginning remote control installation. Failure to do so could result in personal injurg or damage to the electrical controls.
Installation Preparation REMOTE MOUNTING (WIRED) {CONT.) OF THE CONTROL WALL MOUNT COUNTERTOP Wall bracket Control • , _"-"r"--..Co nne cto r 4-wire cordi-._" : _ Mounting Screws 4,-_ Mounting bracket _ Control Jack plate Screws, __ord _-Apply silicone around _cutout Mounting bracket ¼ plate I. Cut out opening into the woll surface. Cutout dimensions are 1-11/16" x 3-11/16". opening 2. Loosen the/4 thumbscrews control from the insert sleeve.
Installation Instructions [STEP I] INSTALL HOOD LINER 1. Frame the cutout opening to fit the linen NOTE: The opening support must be 3/4" thick wood to accept the liner installation screws. 3. Secure the liner to the cabinet with 6 screws provided. 2. Slide the liner up Qnd into the opening until flush with bottom edges.
Installation Instructions [STEP 2] CONNECT ELECTRICAL Verifg that power is turned WARNING: off at the source. ,fhouse wiring is not 00000 2-wirewith a ground wire,an electrician willneed to convertexisting wiringto meet these specs. When house wiringisaluminum, be sureto use U.L approved anti-oxidant compound and aluminum-to-copper connectors. \ AVERTISSEMENT : Si le cablage de la maison n'est pas un cablage 5 deux ills avec un fil de terre, un @lectricien doit convertir votre cablage existant 5 ces
Installation Instructions ISTEP 31 INSTALL INSERT SLEEVE ape 1. Tuck the house wiring out of the wag. 2, Install the insert sleeve into the cutout opening of custom cabinet frame. 4. Align 8" duct to exhaust opening of insert sleeve and seal with aluminum tape. ÷ NOTE: House duct should drop to 11-1/2" above bottom edge of insert sleeve or the bottom of the 3/4" cabinet base. 3. Push the insert sleeve straight up through the cutout opening until the temporarg locking clips engage.
Installation Instructions [STEP 4] INSTALL DAMPER PLATE 1. Pick up damper plate assemblg and rotate so that vent side is up and bracket is located on left as gou stand facing hood. ° 3. Secure damper plate assemblg bg placing nuts on bolts and tightening with socket or wrench. 2. Insert damper plate assemblg into insert sleeve and carefullg align with 8" house duct.
Installation ISTEP sl INSTALL Instructions BLOWER MOTOR iioooooii 1. Pick up blower motor and rotate so tabs align with damper plate bracket. 2. Insert blower motor into insert sleeve through cutout opening of custom cabinet frame. 3. Place blower motor on damper plate assemblg bg sliding blower motor tabs into slots of damper plate assemblg. 00000 4.
Installation Instructions ISTEP 7] INSTALL FILTERS [STEP 8] FINALIZE INSTALLATION 1.Check to be sure all tape and packaging materials have been removed. 1. Remove protective film from the filters. 2. Refer to Owner's instructions. Clip 2. Tip the filter into the back tab slots and lift up. While maintaining slight backward pressure on filter, open clip and press into place with two hands. 3.
Notes 22
Notes 23
Note: While performing installations described in this book, safety glasses or goggles should be worn. For Monogram ® local service in your area, call 1.800.444.1845. Note: Product improvement is a continuing endeavor at General Electric. Therefore, materials, appearance and specifications are subject to change without notice.