CONNECT DUCTWORK
Ŷ,QVWDOOGXFWZRUNPDNLQJFRQQHFWLRQVLQGLUHFWLRQRI
airflow as illustrated.
Ŷ3XVKGXFWRYHUWKHH[KDXVWRXWOHWXQWLOLWUHDFKHVWKH
duct stops.
Ŷ6HFXUHMRLQWVLQGXFWZRUNZLWKVKHHWPHWDOVFUHZV
Ŷ:UDSDOOGXFWMRLQWVZLWKGXFWWDSHIRUDQDLUWLJKW
seal.
Ŷ8VHGXFWWDSHWRVHDOWKHIODQJHFRQQHFWLRQ
CAUTION
Do not use sheet metal screws at the
hood flange connection. Doing so will prevent proper
damper operations. Seal connection with tape only.
ATTENTION
Il ne faut pas utiliser de vis
DXWRUDXUGHXVHVjODFRQQH[LRQGXFROOHWGHODKRWWH&HFL
HPSrFKHUDLWOHERQIRQFWLRQQHPHQWGXUHJLVWUH1¶XWLOLVHU
TXHGXUXEDQDGKpVLISRXUDVVXUHUO¶pWDQFKpLWpGXUDFFRUG
4
INSTALL THE HOOD
3ODFHWKHKRRGRQWKHEUDFNHWVDQGVOLGHOHIWRUULJKWWR
center.
$GMXVWWKHLQVWDOODWLRQOHYHOQHVVE\WLJKWHQLQJ
RUORRVHQLQJWKHVFUHZV³$´DWWKHERWWRPRIWKH
brackets.
2. Mark the 2 lower mounting holes.
3. Remove the hood from the wall.
4. Drill a pilot hole in each lower mounting hole
location. The two lower holes can be enlarged to
LIWKH\GLGHQWHUVWXGV7DSDQFKRUVIRUZDOO
fasteners into the bottom holes. Screws should be
inserted by hand into the fasteners to allow anchors
WRH[SDQGDJDLQVWWKHZDOOPDWHULDO5HPRYHWKH
VFUHZVIRU¿QDOLQVWDOODWLRQ
5. Replace the hood on the mounting brackets.
8VLQJWZRODUJHÀDWZDVKHUVVXSSOLHGLQVWDOOZRRG
screws or wall fastener screws.
7LJKWHQVFUHZV³%´ORFDWHGDWWKHWRSRIWKH
mounting bracket against the hood to clamp the
position. Do not overtighten screws.
Bracket Tabs
Screws
“B”
Screws
“A”
Installation Instructions
Screw
Duct Tape
Over Seam
and Screw
Air Flow
Duct Tape
Over Flange
Duct Stops