Installation Sheet

 49-80329 Rev. 5
Installation Instructions
INSTALLATION—RECIRCULATING
5
INSTALL LOWER STRUCTURE TO
UPPER STRUCTURE
Ŷ6OLGHORZHUIUDPHLQWRWKH
upper frame. Match the
marked alignment holes.
Ŷ6HFXUHWKHXSSHUDQGORZHU
IUDPHZLWKVFUHZVRQ
each side of the frame.
7
INSTALL HOOD ATTACHMENT
SCREWS
Ŷ,QVWDOOKRRGDWWDFKPHQWVFUHZVLQWKHERWWRPRI
WKHVXSSRUWDVVKRZQ/HDYH´JDSEHWZHHQ
screw head and support flange.
8
MOUNT THE HOOD ONTO THE
SUPPORT
WARNING
2 people are required to lift and
position the hood onto the mounting bracket.
AVERTISSEMENT
,IIDXWGHX[SHUVRQQHVSRXU
lever et mettre en place la hotte sur le support de
montage.
Ŷ/LIWWKHKRRGWRWKHERWWRP
RIWKHVXSSRUWHQJDJLQJ
the keyhole slots to the 4
mounting screws.
Ŷ7LJKWHQWKHPRXQWLQJ
screws.
Ŷ,QVWDOO
additional
screws as
shown.
6
INSTALL BLOWER/MOTOR
Ŷ5DLVHWKHEORZHU
motor piece toward the
assembled frame.
Ŷ&DUHIXOO\UDLVHWKHPRWRUWR
the marked reference point
while making sure the duct
piece slips over the blower
outlet flange.
Ŷ6HFXUHWKHEORZHUPRWRUWR
WKHIUDPHXVLQJVFUHZV
4 on each side.
Ŷ8VHWDSHWRVHDOWKHGXFW
connection.
Install 4
attachment
screws
Install 6 screws