Installation Preparation
POWER SUPPLY
IMPORTANT- (Please read carefully)
WARNING:
FOR PERSONAL SAFETY,THIS APPLIANCE MUST BE
PROPERLYGROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Code or
prevailing local codes and ordinances.
Electrical supply
This vent hood must be supplied with 120V, 60Hz,
and connected to an individual, properlg grounded
branch circuit, and protected bg a 15- or 20-amp
circuit breaker or time-delag fuse.
• Wiring must be 2-wire with ground.
• If the electrical supplg does not meet the above
requirements, call a licensed electrician before
proceeding.
• Route house wiring as close to the installation
location as possible. Route additional length from
ceiling joists to reach the junction box on the
hood.
• Connect the wiring to the house wiring in
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to a
ground metal, permanent wiring sgstem, or an
equipment-grounding terminal or lead on the hood.
A WARNING: The improper connection
of the equipment-grounding conductor can result
in a risk of electric shock. Check with a qualified
electrician or service representative if gou are in
doubt whether the appliance is properlg grounded.
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
Pencilandtape measure
Safetyglasses
Spirit level
6loves
Hammer
Phillipsscrewdriver
at_
Flashlight
Utility knife
Electricdrill with 5/32" bits,
#2 Phillipsand7/16" socket
Stepladder
UL-listedwire nuts
10mmwrench
Metal snips
Pliers
Masking Wire cutter/stripper
tape
Sabersawor keyholesaw
Aluminized
ducttape Strainrelief for
junctionbox
Plumb
6" roundmetal
duct, lengthtosuit
installation
120V,60Hz.15-or 20-Amp,
2-wirewith ground,properly
groundedbranchcircuit