Installation Instructions

6
Advance Planning
ADVANCE PLANNING
DuctworkPlanning
•Theseventhoodsareequippedfor10"roundductwork.
Forbestperformance,use10"roundductworkonthe
48"widehoods.30"and36"hoodsmaybetransitioned
to8"round.
•Thishoodmaybeventedverticallythroughuppercabi-
nets,sotorceiling.Aducttransitionpieceissupplied
forverticalexhaust.Uselocallysuppliedelbowstovent
horizontally through the rear wall.
•Determinetheexactlocationoftheventhood.
•Plantherouteforventingexhausttotheoutdoors.
•Usetheshortestandstraightestductroutepossible.
Forsatisfactoryperformance,ductrunshould
notexceed150ft.equivalentlengthforanyductcon-
gurations.
•Referto“DuctFittings”charttocomputethe
maximumpermissiblelengthforductrunstotheout-
doors.
•Usemetalductworkonly.
•Installawallcaporroofcapwithdamperattheexterior
opening. Order the wall or roof cap and any transition
needed in advance.
Wall Framing for Adequate Support
•Theseventhoodsareheavy.Adequatestructuralsup-
port must be provided. Hoods must be secured to verti-
cal studs in the wall.
•Itisstronglyrecommendthattheventhoodwith
ductcoverbeonsitebeforenalframingandwall
nishing.Thiswillalsohelptoaccuratelylocatethe
ductwork and electrical service.
Decorative Duct Covers:
Decorativeductcovers,6"and12"high,areavailable
totallmodels.Theductcoverconcealstheductwork
runningfromthetopofthehoodtotheceilingorsot.
Stack one or more duct covers over the top of the hood
to reach your ceiling height.
POWER SUPPLY
IMPORTANT-(Pleasereadcarefully)
WARNING:
FORPERSONALSAFETY,THISAPPLIANCEMUSTBEPROP-
ERLYGROUNDED.
AVERTISSEMENT –POURDESRAI-
SONSDESÉCURITÉ,CETAPPAREILDOITÊTRECORRECTE-
MENTMISÀLATERRE.
Remove house fuse or open circuit breaker before begin-
ning installation.
Donotuseanextensioncordoradapterplugwith
thisappliance.FollowNationalelectricalcodesorpre-
vailing local codes and ordinances.
Electrical supply
These vent hoods must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch
circuit, and protected by a 15 or 20 amp circuit breaker
or time delay fuse.
•Wiringmustbe2wirewithground.
•Iftheelectricalsupplydoesnotmeettheaboverequire-
ments, call a licensed electrician before proceeding.
•Routehousewiringasclosetotheinstallation
location as possible on the back wall or ceiling.
•Connectthewiringtothehousewiringin
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an equip-
ment-grounding terminal or lead on the hood.
WARNING: The improper connection of the
equipment-grounding conductor can result in a risk
ofelectricshock.Checkwithaqualiedelectricianor
service representative if you are in doubt whether the
appliance is properly grounded.
AVERTISSEMENT
Lemauvaisbranchementduldemiseàlaterrepeut
causer un choc électrique. En cas de doute, consulter un
électricienqualiéouuntechnicienpourdéterminersi
l’appareilestàlaterre.