Installation Instructions
4
Advance Planning
INSTALLATION CLEARANCES
These vent hoods are designed to be installed onto a wall
orbeneathasotorcabinet.
Installation with Warming Shelf
•Hoodsmustbeinstalled32"min.,38"max.overanytype
cooking surfac when warming shelf is used.
Installation without Warming Shelf
•Installthesehoods30"min.to36"max.abovethecook-
ing surface when installed over any professional style
cooktop or range.
•Thesehoodsmaybeinstalled24"min.aboveagasor
electric drop-in style cooktop.
In this installation the ductwork running from the top
ofthehoodwillbeconcealedinthesotorupper
cabinetry.
Installthesehoods30"min.to
36"max.overaprofessional
style cooktop or range.
Installthesehoods30"min.to
36"max.overaprofessional
style cooktop or range.
Allow32"min.and36"max.
clearance above any cooking
surface when installed with shelf.
Allow32"min.and36"max.
clearance above any cooking
surface when installed with shelf.
Forthisinstallation,adecorativeductcoverisavailable
to conceal the ductwork running from the top of the
hood. Use of the duct cover requires special consider-
ation to the installation height above the countertop.
Note: Clearances may vary due to type of cooking product
and local codes. Check with local inspectors to be sure stan-
dard is applicable.
OPTIONAL DUCT COVER
ACCESSORIES
Standarddecorativeductcoversareavailablein6"and
12"heights.Ductcoversmaybestacked,invariouscom-
binations, to conceal the ductwork running from the top
of the hood to the ceiling.
•Beforeyoubegin,youshoulddeterminethe
installation height of the hood and order the correct
size duct cover. The duct covers should be ordered at
the same time as the vent hood and be on site before
installation. Order the duct cover corresponding to your
model.
6" Duct Cover
12" Duct Cover
Standard Duct Covers
6" Duct Covers
Hood Model 6” Duct Cover Dimensions
ZV48R ZX48DC6 6"Hx19-11/16"Wx11-7/8"D
ZV36R ZX36DC6 6"Hx15-3/4"Wx11-7/8"D
ZV30R ZX36DC6 6"Hx15-3/4"Wx11-7/8"D
12" Duct Covers
Hood Model 12” Duct Cover Dimensions
ZV48R ZX48DC12 12"Hx19-11/16"Wx11-7/8"D
ZV36R ZX36DC12 12"Hx15-3/4"Wx11-7/8"D
ZV30R ZX36DC12 12"Hx15-3/4"Wx11-7/8"D
SOFFIT
SOFFIT
Soffit Installation
32" Min.
38" Max.
30" Min.
36" Max.
Wall Mount Installation
32" Min.
38" Max.
30" Min.
36" Max.