Installation Guide
14 31-2000856 Rev. 0
Installation Instructions
3
CONNECT DUCTWORK
Ŷ,QVWDOOGXFWZRUNPDNLQJFRQQHFWLRQVLQGLUHFWLRQRI
airflow as illustrated.
Ŷ6HFXUHMRLQWVLQGXFWZRUNZLWKVKHHWPHWDOVFUHZV
Ŷ:UDSDOOGXFWMRLQWV
with duct tape for an
airtight seal.
Ŷ8VHGXFWWDSHWR
seal the flange
connection. Reach
inside the hood and
push the damper up
to be sure it moves
freely.
5
INSTALL DUCT COVERS
NOTE: )RUHDVLHUKDQGOLQJUHPRYHFDUGERDUGLQVHUW
after film is peeled off.
Remove protective film from duct covers. If more than
RQHGXFWFRYHULVXVHGVHFXUHHDFKSLHFHWRJHWKHU
with screws provided.
Ŷ3ODFHWKHGXFWFRYHUVRQWRSRIWKHKRRG
Ŷ)URPLQVLGHWKHKRRGVHFXUHWKHGXFWFRYHUWRWKH
WRSZLWKWKHVPDOO3KLOOLSVKHDGVFUHZVVXSSOLHG
with the covers.
6
INSTALL MOTOR
Ŷ)URPWKHLQVLGHRIWKHKRRGVOLSPRWRULQWRWKH
attachment slot on the left.
Ŷ5RWDWHPRWRUXSZDUGVXQWLOLWVQDSVLQWRWKHVSULQJ
clip on the right.
Ŷ6HFXUHWKHPRWRUWRWKHKRRGZLWKWKHPDFKLQH
screw and lock washer. (Screw is marked with red
or blue paint.)
Ŷ3OXJFRQQHFWRULQWRWKHPRWRU
IMPORTANT: Connector ends are designed to mate
only one way. Match flat and round connectors as
shown.
4
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
If house wiring is not 2-wire with
DJURXQGZLUHDJURXQGPXVWEHSURYLGHGE\WKH
LQVWDOOHU:KHQKRXVHZLULQJLVDOXPLQXPEHVXUH
WRXVH8/DSSURYHGDQWLR[LGDQWFRPSRXQGDQG
aluminum-to-copper connectors.
AVERTISSEMENT
6LOHFkEODJHGHODPDLVRQ
Q¶HVWSDVGXW\SHjGHX[ILOVDYHFXQILOGHWHUUH
O¶LQVWDOODWHXUGRLWIRXUQLUXQFLUFXLWGHWHUUH4XDQGOHV
ILOVGHODPDLVRQVRQWHQDOXPLQLXPLOSUHQGUHVRLQ
G¶XWLOLVHUGHODSkWHDQWLR[LGDWLRQDSSURXYpHSDU8/HW
des connecteurs pour l’aluminium-cuivre.
ADVERTENCIA
Si el cableado del hogar no tiene
FDEOHVFRQXQRDWLHUUDHOLQVWDODGRUGHEHUiSURYHHUXQD
FRQH[LyQDWLHUUD&XDQGRHOFDEOHDGRGHOKRJDUVHDGH
DOXPLQLRDVHJ~UHVHGHXVDUXQFRPSXHVWRDQWLR[LGDQWH\
conectores de aluminio a cobre aprobados por U.L.
Ŷ8VHZLUHQXWVWR
connect incoming
JURXQGWRJUHHQ
white to white and
black to black.
Ŷ3XVKZLUHVLQWR
MXQFWLRQER[DQG
replace cover. Be
sure wires are not pinched.
Screw
Duct Tape
Over Seam
and Screw
Air Flow
Duct Tape
Over Transition
White
Ground
Black
Remove
Junction Box
Cover
Insert Power
Conduit Thru
Strain Relief
and Tighten
Use UL Listed
Wire Nuts
A
B
C
Top
Attachment
Screw
Spring
Clip
Spring
Clip
Outlet
A
ttachment
Slot