Installation Instructions
4
Advance Planning
INSTALLATION CLEARANCES
These vent hoods are designed to be installed onto a wall
orbeneathasotorcabinet.
•Installthesehoods*30"Min.to36"Max.abovethe
cooking surface.
*Thesehoodsmaybeinstalled24"min.aboveagasor
electricdrop-instylecooktop.Alwaysobservethe30"to
36"clearancewheninstalledoveranyprofessionalstyle
cooktop or range.
In this installation the ductwork running from the top
ofthehoodwillbeconcealedinthesotorupper
cabinetry.
Forthisinstallation,adecorativeductcoveris
available to conceal the ductwork running from
the top of the hood. Use of the duct cover requires
special consideration to the installation height above
the countertop.
Note: Clearances may vary due to type of cooking product
and local codes. Check with local inspectors to be sure stan-
dard is applicable.
SOFFIT
Soffit Installation
30" MIN.
36" MAX.
Wall Mount Installation
30" MIN.
36" MAX.
OPTIONAL DUCT COVER
ACCESSORIES
Standarddecorativeductcoversareavailablein6"and
12"heights.Ductcoversmaybestacked,invariouscom-
binations, to conceal the ductwork running from the top
of the hood to the ceiling.
•Beforeyoubegin,youshoulddeterminethe
installation height of the hood and order the correct
size duct cover. The duct covers should be ordered at
the same time as the vent hood and be on site before
installation. Order the duct cover corresponding to your
model.
6" Duct Cover
12" Duct Cover
Standard Duct Covers
6" Duct Covers
Hood Model 6” Duct Cover Dimensions
ZV48T,ZV48S ZX48DC6 6"Hx19-11/16"Wx11-7/8"D
ZV36T,ZV36S ZX36DC6 6"Hx15-3/4"Wx11-7/8"D
ZV30T,ZV30S ZX36DC6 6"Hx15-3/4"Wx11-7/8"D
12" Duct Covers
Hood Model 12” Duct Cover Dimensions
ZV48T,ZV48S ZX48DC12 12"Hx19-11/16"Wx11-7/8"D
ZV36T,ZV36S ZX36DC12 12"Hx15-3/4"Wx11-7/8"D
ZV30T,ZV30S ZX36DC12 12"Hx15-3/4"Wx11-7/8"D