Installation Instructions

4
Advance Planning
INSTALLATION CLEARANCES
These vent hoods are designed to be installed onto a wall
orbeneathasotorcabinet.
•Installthesehoods*30"Min.to36"Max.abovethe
cooking surface.
*Thesehoodsmaybeinstalled24"min.aboveagasor
electricdrop-instylecooktop.Alwaysobservethe30"to
36"clearancewheninstalledoveranyprofessionalstyle
cooktop or range.
In this installation the ductwork running from the top
ofthehoodwillbeconcealedinthesotorupper
cabinetry.
Forthisinstallation,adecorativeductcoveris
available to conceal the ductwork running from
the top of the hood. Use of the duct cover requires
special consideration to the installation height above
the countertop.
Note: Clearances may vary due to type of cooking product
and local codes. Check with local inspectors to be sure stan-
dard is applicable.
SOFFIT
Soffit Installation
30" MIN.
36" MAX.
OPTIONAL DUCT COVER
ACCESSORIES
Standarddecorativeductcoversareavailablein6"and
12"heights.Ductcoversmaybestacked,invariouscom-
binations, to conceal the ductwork running from the top
of the hood to the ceiling.
•Beforeyoubegin,youshoulddeterminethe
installation height of the hood and order the correct
size duct cover. The duct covers should be ordered at
the same time as the vent hood and be on site before
installation. Order the duct cover corresponding to your
model.
Standard Duct Covers
6" Duct Covers
Hood Model 6” Duct Cover Dimensions
ZV48T,ZV48S ZX48DC6 6"Hx19-11/16"Wx11-7/8"D
ZV36T,ZV36S ZX36DC6 6"Hx15-3/4"Wx11-7/8"D
ZV30T,ZV30S ZX36DC6 6"Hx15-3/4"Wx11-7/8"D
12" Duct Covers
Hood Model 12” Duct Cover Dimensions
ZV48T,ZV48S ZX48DC12 12"Hx19-11/16"Wx11-7/8"D
ZV36T,ZV36S ZX36DC12 12"Hx15-3/4"Wx11-7/8"D
ZV30T,ZV30S ZX36DC12 12"Hx15-3/4"Wx11-7/8"D