Specifications

ZV36RSFSSMONOGRAM 36" STAINLESS STEEL PROFESSIONAL HOOD
Listed by
Underwriters
Laboratories
Product Specification Revised 1/18
USING DUCT COVER ACCESSORIES
To avoid unsightly gaps, plan the hood installation
height for duct covers use. Use the following formula to
calculate the need for one of more duct covers and to
ensure a trouble free installation.
We recommend that the vent hood and decorative
duct cover (if used) be on site before nal framing and
wall nishing. This will help to accurately locate studs,
ductwork and electrical service.
Read these examples carefully to determine the need
for one or more 6" or 12" duct covers.
A = Countertop to ceiling height.
B = Gap at the top of the hood to the ceiling.
C = Hood installation height – Plus 10" hood height.
NOTE
Dia. C should be between 40" and 46" (for a 30" to 36"
installation height). Raise or lower the hood installation
height to allow use of one or more 6" and 12" duct covers.
INSTALLATION EXAMPLES
CEILING HEIGHT
A - B = C
Ceiling Height
A
C
B
10" Hood
Height
INSTALLATION EXAMPLES
32"
12"
38"
24"
32"
42"
INSTALLATION EXAMPLES
32"
12"
38"
24"
32"
42"
10 FT. CEILINGS
When the hood is
installed 36" above
the cooking surface,
order three 12" and
one 6" duct cover
accessories.
9 FT. CEILINGS
When the hood is
installed 38" above
the cooking surface,
order two 12" duct
cover accessories.
8 FT. CEILINGS
When the hood is
installed 32" above
the cooking surface
and there is no sot
or upper cabinetry,
order one 12" and
one 6" duct cover
accessory.