STEP 4 MOUNT TEMPLATE
• Align the template with the marks on the ceiling and
tape in place.
– Be sure the template is oriented correctly, with the
front of the hood.
• Use a plumb to check to be sure the mounting holes
will provide parallel alignment with the countertop
below.
• Center punch all hole locations.
• Drill pilot holes in the 4 screw locations. Use a 5/32”
bit and drill approximately 1-1/2” deep.
• Cut the 8-1/4" duct opening and approx. 1" wire
access hole.
Installation Instruction
STEP 5 INSTALL SUPPORT FRAME
Install upper support frame
• Secure the upper support frame to the ceiling joists
and cross framing with the 4 lag screws provided. For
maximum rigidity and strength, the screws must be
driven into the center of the joists and/or cross
framing.
Check to be sure the support frame is level, vertically
and horizontally.
Install lower support frame
• Insert lower support frame (or accessory support
frame, ZX1059SFSS or ZX10510SFSS) into the upper
support frame and loosely secure with 8 screws and
washers. (4 on the front and 4 on the back sides)
• Adjust the lower support frame up or down to the
desired height above the countertop. Tighten screws.
IMPORTANT: Again, check to be sure the support is
level in both directions. There is no way to level the
hood after the hood is secured to the frame.
30" Recommended
10"
40"
Countertop
Hood
Mounting
Flange
Lower Support
76"
Wire Access Holes
Support
Frame
Opening
Upper
Support
Frame
Lower
Support
Frame
Check Level in
Both Direction
Front
Of
Hood