Product Specifications
SIDE VIEW
FRONT VIEW
TOP VIEW
28 1/2" (72.4)
min. cutout width
23 1/2" (59.7)
min. cutout depth
1/4"
(.6)
min.
1"
(2.5)
min.
Above
toe-kick
2" (5.1) min.
Between cut-outs
2" (5.1) x 4" (10.2)
or Equivalent Runners
Install
2" (5.1) x 4" (10.2)
or
2" (5.1) x 2" (5.1)
Anti-tip Block against
rear cabinet wall 9" from
floor to bottom of block
Side cleats
9 1/4"
(23.5)
Cut-out
height
30" (76.2)
25" (63.5)
23 1/2"
(59.7)
2" (5.1) x 4" (10.2)
or
2" (5.1) x 2" (5.1)
Runners or Solid Bottom
ZTW900PSNSS
For questions about your
appliance, please call 1-800-626-2000.
Product Specication Created 10/19
HELPFUL TIPS
PAGE 4 OF 6
A
If you are installing in frameless cabinets, it
may be necessary to install 1/2" wide cleats to
accept drawer mounting screws. See drawer
for mounting screw locations.
B
Install a 2"x2" or 2"x4" anti-tip block against
rear wall, 9" from floor of cutout to bottom
of block. e anti-tip block must be installed
to prevent the drawer from tipping forward
when opened and loaded. Failure to add the
anti-tip block could result in personal injury.
C
When installing the warming drawer below
a cabinet drawer, a solid barrier must be
installed at least above the warming drawer
to block access. Use any solid material such
as 1/4" thick plywood. Allow at least 1/4"
air gap between the barrier and the top of
the warming drawer. Observe the 5" min.
above the floor or 1" min. above the toe kick
installation height.
D
When installing two warming drawers side
by side, install them in separate cut-outs and
allow a 2" min. gap between each cut-out.
E
e warming drawer may be supported
by either a solid bottom or 2"x2" or 2"x4"
runners. e support must be level and
rigidly mounted, flush with the bottom edge
of the cut-out (there is no way to level the
drawer once it has been installed, so make
sure that the supports are level). e floor
or runners must be capable of supporting
at least 150 lbs.
For more details refer to the installation
instructions for this product.
INSTALLATION BELOW A CABINET DRAWER
PROVIDING CABINET SUPPORT INSTALLING ANTI-TIP BLOCKS
SIDE BY SIDE INSTALLATION
SIDE VIEW
FRONT VIEW
TOP VIEW
28 1/2" (72.4)
min. cutout width
23 1/2" (59.7)
min. cutout depth
1/4"
(.6)
min.
1"
(2.5)
min.
Above
toe-kick
2" (5.1) min.
Between cut-outs
2" (5.1) x 4" (10.2)
or Equivalent Runners
Install
2" (5.1) x 4" (10.2)
or
2" (5.1) x 2" (5.1)
Anti-tip Block against
rear cabinet wall 9" from
floor to bottom of block
Side cleats
9 1/4"
(23.5)
Cut-out
height
30" (76.2)
25" (63.5)
23 1/2"
(59.7)
2" (5.1) x 4" (10.2)
or
2" (5.1) x 2" (5.1)
Runners or Solid Bottom
ZTW900PSNSS
SIDE VIEW
FRONT VIEW
TOP VIEW
28 1/2" (72.4)
min. cutout width
23 1/2" (59.7)
min. cutout depth
1/4"
(.6)
min.
1"
(2.5)
min.
Above
toe-kick
2" (5.1) min.
Between cut-outs
2" (5.1) x 4" (10.2)
or Equivalent Runners
Install
2" (5.1) x 4" (10.2)
or
2" (5.1) x 2" (5.1)
Anti-tip Block against
rear cabinet wall 9" from
floor to bottom of block
Side cleats
9 1/4"
(23.5)
Cut-out
height
30" (76.2)
25" (63.5)
23 1/2"
(59.7)
2" (5.1) x 4" (10.2)
or
2" (5.1) x 2" (5.1)
Runners or Solid Bottom
ZTW900PSNSS
A
A
D
E
B
B
C