A
Mounting the junction box in this
location will also allow for front
accessibility through access panel.
B
Water supply area
WARNING:
e refrigerator is top heavy and
must be secured to prevent the
possibility of tipping forward.
Failure to do so may result in
death or serious injury.
e information below is for
cabinet design only. When
installing the anti-tip system
you must use the product
installation instructions.
e information below applies to all
installation constructions:
• A wall bracket, bolts and toggles will
be supplied with the unit.
• e bolts will be used to attach
bracket to wall in 4 locations. Two
of the locations must penetrate the
center of the wall studs.
• e toggles are used for stability in
drywall and when metal studs are
encountered. Lag bolts are used in
wood studs.
• In installation opening, measure
81-1/2" from
floor and draw a horizontal line.
• Locate and mark the wall studs on
horizontal line. Verify at least two
studs have their centerlines within
the center 32-1/2"
of installation opening to ensure 2
wall studs are penetrated.
• e bracket will be centered left
to right in opening with bottom of
bracket on the horizontal line.
• When unit is placed in opening, the
bracket tabs will align with openings
in back of the unit. e unit will be
secured to the bracket using supplied
“L” bolts.
See Installation Instructions for
detailed instructions.
Use two
additional hole
locations at
end of
brackets
Wall
Studs
Bracket
mounted
into vertical
wall studs
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
35 1/2" (90.2)
2 5/16"
(5.9)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5 )
From floor
to bottom
of electrical
area
23 5/8" (60)
2 3/8"
(6)
7/16"
(1.1)
Trim overlap
4 7/8"
(12.4)
SIDE VIEWFRONT VIEW
ELEC.
6"
(15.2)
10"
(25.4)
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
ZICP360NXLH
81 1/2"
(207.0)
FRONT VIEW
WATER
5"
(12.7)
5"
(12.7)
3 1/2"
(9.0)
WATER
10" (25.4)
Use two
additional hole
locations at
end of
brackets
Wall
Studs
Bracket
mounted
into vertical
wall studs
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
35 1/2"
(90.2)
2 5/16"
(5.9)
*83 1/2
" min
*84 1/2
" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5 )
From floor
to bottom
of electrical
area
23 5/8"
(60)
2 3/8"
(6)
7/16"
(1.1)
Trim overlap
4 7/8"
(12.4)
SIDE VIEWFRONT VIEW
ELEC.
6"
(15.2)
10"
(25.4)
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
ZICP360NXLH
81 1/2"
(207.0)
FRONT VIEW
WATER
5"
(12.7)
5"
(12.7)
3 1/2"
(9.0)
WATER
10" (25.4)
DUAL INSTALLATIONS
A
ANTI-TIP BRACKET
B
HELPFUL TIPS