Installation Sheet
6
 MAKE ELECTRICAL CONNECTIONS
WARNING
:
 Switch power off at the service panel and lock the service disconnecting 
means to prevent power from being switched on accidentally. When the service disconnecting means 
cannot be locked, securely fasten a prominent warning device, such as a tag, 
to the service panel.
Place oven on table or platform even with the cutout opening. For a single oven, the platform must support 
220 lbs. (99 kg); and for a double oven, the platform must support 400 lbs. (181 kg). Connect the flexible 
conduit to the electrical junction box as shown below*. Position the conduit in such a manner that it will lie 
behind the unit in a natural loop when the oven is installed. You will need to purchase an appropriate strain 
relief clamp to complete the connection of the conduit to the junction box.
* Ovens come equipped with a 40” long conduit. If a longer conduit is desired, there may be one available for 
your model. To check availability or order parts, call 1.800.GE.CARES.
7
 THREE-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE: If residence leads are aluminum conductors, see WARNING 
in Section 5, Electrical Requirements.
When connecting to a three-conductor branch circuit, if local codes 
permit:
A. Connect the bare oven ground conductor with the crimped 
neutral (white) lead to the branch circuit neutral (white or gray in 
color), using a wire nut.
B.  Connect the oven red lead to the branch circuit red lead 
and the oven black lead to the branch circuit black lead 
in accordance with local codes, using wire nuts.
C. Install junction box cover.
Junction Box 
Conduit
Bare 
Ground
Red
White
Black
Strain Relief Clamp 
(not included) Must Be 
Used at Junction Box
Place Oven on a 
Support to Assist in 
Connecting Conduit
Ground 
and Neutral 
Wires
Junction Box 
Cover
Ground 
Wire
8
 FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE: If residence leads are aluminum conductors, see WARNING in Section 5, Electrical Requirements.
A. Cut the neutral (white) lead from the crimp. Re-strip the neutral (white) lead to expose 
the proper length of conductor.
B. Attach the appliance grounding lead (green or bare copper) 
in accordance with local codes. If the residence grounding 
conductor is aluminum, see WARNING in Section 5.
C. Connect the oven neutral (white) lead to the branch circuit 
neutral (white or gray) in accordance with local codes, using 
a wire nut.
D. Connect the oven red lead to the branch circuit red lead 
and the oven black lead to the branch circuit black lead 
in accordance with local codes, using wire nuts. 
NOTE: If the residence red, black or white leads are aluminum 
conductors, see WARNING in Section 5.
E. Install junction box cover.
9
 SLIDE OVEN INTO OPENING
•  Lift oven into cabinet cutout using the 
oven opening as a grip. Carefully push 
against oven front frame. Do not push 
against outside edges.
Ground 
Wire
Junction Box 
Cover