Owner`s manual
Design Guide
SIDE PANELS
Side panels must be used
whenever the sides of the
refligerator will be
exposed. The 1/4" side
panels will slip into the
side case trim. Secure the
panels to the refligerator
with s0ck-on hook and
loop fastener strips. Order
the side panels flom the
cabinet manufactureL
• Cut a notch in the top
fFoIlt coIIleI as showIl
to allow clearance for
corner keys in the flont
side trim.
*84"
,_ q_*3" to 4"
11
2-9/16"
* Dependingon installation
height,
TOOLS REQUIRED
• Tinsnips to cut banding
• Stepladder
• Bucket
• l,evel
• Appliance Hand Truck
• Tubing cutter
• 7/116" open-end wrench
• #2 Phillips screwdriver
• Drill and appropriate bits
• 5/16", 7/16" socket
• Safety glasses
• 1-1/4" open end wrench
• Pliers
• 1/4" ratchet wrench
HARDWARE SUPPLIED
• Water filter bypass plug
• And-Tip brackets
• 1/4" nut and ferrule
• Dispenser uims for 1/4" and 3/4" overl W panels
• 12 pan head screws for custom handle installation
MATERIALS REQUIRED
• 35" long 2x4 for Anti-Tip support
• 1/4" copper water line robing or GE
SmartConnect TM Refligerator Tubing kits
• Water shut-off vane (optional but recommended)
• Custom panels for doors and grille panel
• Screws to secure refligerator to cabinetry
• S0ck-on hook and loop fastener strips for
1/4" side panels
FLOORING
For proper installation, tiffs refligerator must be
placed on a level surface of hard material that is
at tim same height as tim rest of tim flooring. This
surface should be suong enough to support a fidly
loaded refligeratoI, or approximately 1,500 lbs.
NOTE: Protect the finish of the flooring. Cut a large
section of the cardboard carton and place under the
refligerator where you are working.
GROUNDING THE REFRIGERATOR
IMPORTANT - (Please read carefully)
FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERIX GROUNDED.
The power cord of tiffs appliance is equipped with
a three-prong (grounding) plug which mates with a
standard three-prong (grounding) wall receptacle to
minimize the possibility of elecuic shock hazard
flom this appliance.
Have tim wall oudet and circuit checked by a
qualified elecuician to make sure the outlet is
properly grounded.
Where a standard 2-prong wall oudet is encountered,
it is your personal responsibility and obligation to
have it replaced with a properly grounded 3-prong
wall outlet.
DO NOT, UNDER ANY
CIRCUMSTANCES, CUT
OR REMOVE THE THIRD
(GROUND) PRONG
FROM THE POWER CORD.
DO NOT USE AN ADAPTER PI,UG TO CONNECT
THE REFRIGERATOR TO A 2-PRONG OUTI,ET.
DO NOT USE AN EXTENSION CORD WITH THIS
APPI fiANCE.
10