Specifications
NOTES
ZIRS360NHRHMONOGRAM 36" BUILT-IN ALL-REFRIGERATOR
Product Specification Revised 1/18
71 1/2" (181.6)
Finished Width
24" (61.0)
Min. Cutout Depth
24 3/16" (61.4)
2 5/16"
(5.9)
5 1/2"
(13.9)
9"
(22.9)
83 1/2" min
84 1/2" max
(212.1-214.6)
Finished Opening
3 1/2"
(8.9)
ZIF360NXLH_ZIF360NXRH _ZIFP360NXLH_ZIFP360NXRH_ ZIFS360NXLH_ZIFS360NXRH
ZIR360NXLH_ZIR360NXRH_ZIRP360NXLH_ZIRP360NXRH_ZIRS360NXLH_ZIRS360NXRH
W
FRONT VIEW
ELEC.
5 1/2"
(13.9)
9"
(22.9)
3 1/2"
(8.9)
25" (63.5) min
To wall
25" (63.5) min
To wall
5" (12.7) min
15" 
(38.1) min
To wall
1"
(2.5)
2" min
(5.1)
130˚
Door swing
130˚
Door swing
75 1/2"
(191.8 )
From floor
to bottom
of electrical
area
ELEC.
SIDE VIEW
5"
(12.7)
5"
(12.7)
5"
(12.7)
5"
(12.7)
WATER
3 1/2"
(9.0)
WATER
3 1/2"
(9.0)
DUAL INSTALLATIONS
A
DUAL PRODUCT CLEARANCES
71 1/2" (181.6)
Finished Width
24" (61.0)
Min. Cutout Depth
24 3/16" (61.4)
2 5/16"
(5.9)
5 1/2"
(13.9)
9"
(22.9)
83 1/2" min
84 1/2" max
(212.1-214.6)
Finished Opening
3 1/2"
(8.9)
ZIF360NXLH_ZIF360NXRH _ZIFP360NXLH_ZIFP360NXRH_ ZIFS360NXLH_ZIFS360NXRH
ZIR360NXLH_ZIR360NXRH_ZIRP360NXLH_ZIRP360NXRH_ZIRS360NXLH_ZIRS360NXRH
W
FRONT VIEW
ELEC.
5 1/2"
(13.9)
9"
(22.9)
3 1/2"
(8.9)
25" (63.5) min
To wall
25" (63.5) min
To wall
5" (12.7) min
15" 
(38.1) min
To wall
1"
(2.5)
2" min
(5.1)
130˚
Door swing
130˚
Door swing
75 1/2"
(191.8 )
From floor
to bottom
of electrical
area
ELEC.
SIDE VIEW
5"
(12.7)
5"
(12.7)
5"
(12.7)
5"
(12.7)
WATER
3 1/2"
(9.0)
WATER
3 1/2"
(9.0)
B C
D
A
  A separate 115V, 60Hz, 
15- or 20-amp power supply is 
recommended for each product.
Additional cutout width may be 
required when side panels are used.
B
  In a side-by-side installation of a 
left-and-right-hand door swing 
product, 1" clearance between the 
units is required. Order ZUGSS2 
European, ZUGPP2 Professional or 
ZUG2 custom panel unified grille 
kit for one continuous grille panel.
C
  In a side-by-side installation 
with same door swing, allow 2" 
minimum clearance between the 
products to prevent the door 
swing interference. Allow 15" 
minimum to a wall to achieve 
full drawer extension and pan 
removal. Additional clearances 
are required when using custom 
panels and handles. 
NOTE: ZUG2, ZUGSS2 or ZUGPP2 
grille panel kits will not fit this 
installation.
D
  In a side-by-side installation 
with right and left door hinges 
together, allow 5" minimum 
clearance between the two 
products to prevent one door 
from striking the other. Additional 
clearances required when using 
custom panels and handles. 
NOTE: ZUG2, ZUGSS2 or ZUGPP2 
grille panel kits will not fit this 
installation.