Quick Specs
Product Specication Created 11/20
SINGLE INSTALLATION
The nished cutout width must be 30". The cutout depth must
be 25" for ush installations.
- The front face of the refrigerator ts ush with 25"depth
adjacent cabinets.
ELECTRICAL
A 115V, 60Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall. Electrical must
be located on rear wall as shown.
NOTE: GFI (ground fault interrupter) is not recommended.
WATER LINE
- A cold water supply is required for automatic icemaker
operation. The water pressure must be between 40 and
120 p.s.i.
- Route 1/4" OD copper or GE SmartConnect
™
plastic tubing
between the house cold water line and the water connection
location.
- Tubing should be long enough to extend to the front of the
refrigerator. Allow enough tubing to accommodate a bend
leading into the water line connection.
- Water line can enter an opening through the oor or
back wall.
- Install a shut-o valve between the icemaker water valve
and cold water supply in the home.
NOTE: When two units are placed side by side, order heater
kit ZUG30.
PAGE 3 OF 8
For questions about your
appliance, please call 1-800-626-2000.
WARNING:
When installing appliance, you must use and follow
the product installation instructions. These can be
found with unit or on web at monogram.com.
This document is intended for cabinet and panel
construction only.
THE INSTALLATION SPACE
Height options
80" or * 84"
25" min. depth
30" Finished Width
60" shed Width
Wall
View
84"
max
80"
min
Finished
Opening
25"min. Cutout
epth
77"
6"
Anti-tip location do not obstruct
Water Tube & Electrical Outlet
Fini
D