Installation Instructions
29
31-1000169 Rev. 5
Installation Instructions
INSTALLATION INSTRUCTIONS FOR MULTIPLE UNITS (cont.)
STEP 13 CONNECT HEATER (Cont.)
Ŷ,QVWDOO+HDWHU:LUH6WUDLQ5HOLHILQ*ULOOH6ORW.
Ŷ,QVWDOO7UDQVIRUPHUWRZDOODWOHIWRIFRSSHUWXELQJ
1. Disconnect EMI filter from main power connector at 
left leg of product.
Connect:
2. Main power of “Y” splitter harness to main power at 
left of product.
3. EMI filter (blk/wht) to “Y” splitter EMI filter (grn/blk). 
4. Transformer (blk) to “Y” splitter transformer (blk/wht).
5. Transformer (red) to side heater.
STEP 14 LEVEL UNITS
All models have 4-point leveling. The front is supported 
E\OHYHOLQJOHJVWKHUHDULVVXSSRUWHGE\DGMXVWDEOH
wheels. Both are accessible from the front of the unit.
Ŷ7ROHYHOWKHEDFNRIWKHXQLWWXUQWKHƎKH[
nut located above the front wheels. Turn counter 
clockwise to raise or clockwise to lower the unit.
Ŷ)RUIURQWOHYHOLQJXVHDƎRSHQHQGZUHQFK
ŶAdjust height of unit to match installation cutout 
opening. The unit should be level and plumb with 
cabinetry. 
NOTICE: The rear leveling wheels and front leveling 
OHJVDUHOLPLWHGWRDPD[LPXPKHLJKWDGMXVWPHQWRIƎ
,IWKHLQVWDOODWLRQUHTXLUHVPRUHWKDQƎKHLJKWWKH
installer should elevate the unit on a sheet of plywood 
or runners. Cabinetry trim could also be added across 
the top of the opening to shorten the opening. 
,I\RXDWWHPSWWRUDLVHWKHXQLWPRUHWKDQƎ\RXZLOO
damage the front leveling legs and the rear leveling 
wheels.
Up
Leveling Leg
Up
Hex Nut Adjusts 
Rear Wheels
2
2
5
5
4
3
3
4
1
Heater 
wire 
strain 
relief
To side 
heater
EMI filter
To EMI 
filter
Side heater To transformer
To transformer “Y” splitter
To main power
“Y” splitter 
jumper harness
To main power
To EMI filter
To heater
To main power
thru “Y” splitter