Spec Sheet

For questions about your
appliance, please call 1-800-626-2000.
Product Specication Created 10/19PAGE 10 OF 17
FLUSH INSET
INSTALLATION
HELPFUL TIPS
FLUSH INSTALLATION
ZIF360NHLH_RH
ZIR360NHLH_RH
39" (99.1) Flush inset width
37 1/2" (95.3)
Width between cleats
7"
(17.8)
7"
(17.8)
3/4" (1.9)
Width of side cleats
5 1/4" (13.3)
1/2" (1.3)
26 3/16" (66.5)
Flush inset depth
20 15/16" (53.2)
Depth to cleat
FRONT VIEWSIDE VIEW
TOP VIEW
3 1/2"
(8.9)
W
Finished cleats
Finished cleats
Case Trim
3/4" Panel
Case
Door
5 1/2"
(14.0)
24 3/16"
(61.4)
9"
(22.9)
ELEC.
3 1/2"
(8.9)
75 1/2"
(191.8 )
From floor
to bottom
of electrical
area
WATER
3 1/2"
(9.0)
85"
(215.9)
85"
(215.9)
C
B
ANTI-TIP BRACKET
SIDE VIEW
W
25 3/8" (64.5)
1 1/2"
(3.8)
7/16"
(1.1)
Trim overlap
3 1/2"
(8.9)
FRONT VIEW
ELEC.
35 1/2" (90.2)
2 5/16"
(5.9)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75
1/2
"
(191.8)
From floor
to bottom
of electrical
area
5 1/2"
(14.0)
9"
(22.9)
ZIF360NXRH
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
5"
(12.7)
5"
(12.7)
WATER
3 1/2"
(9.0)
81 1/2"
(207.0)
Use two
additional hole
locations at
end of
brackets
Wall
Studs
Bracket
mounted
into vertical
wall studs
centered
within the
cutout
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
A
Mounting the junction box in this
location will also allow for front
accessibility through access panel.
B
Water supply area.
C
Top cleat should be 1" thick
WARNING:
e freezer is top heavy and must
be secured to prevent the possibility
of tipping forward. Failure to do so
may result in death or serious injury.
e information below is for
cabinet design only. When installing
the anti-tip system you must use the
product installation instructions.
e information below applies to all
installation constructions:
A wall bracket, bolts and toggles will
be supplied with the unit.
e bolts will be used to attach
bracket to wall in 4 locations. Two
of the locations must penetrate the
center of the wall studs.
e toggles are used for stability in
drywall and when metal studs are
encountered. Lag bolts are used in
wood studs.
In installation opening, measure
81 1/2" from floor and draw a
horizontal line.
Locate and mark the wall studs on
horizontal line. Verify at least two
studs have their centerlines within the
center 32 1/2" of installation opening
to ensure 2 wall studs are penetrated.
e bracket will be centered left to
right in opening with bottom of
bracket on the horizontal line.
When unit is placed in opening, the
bracket tabs will align with openings
in back of the unit. e unit will be
secured to the bracket using supplied
“L” bolts.
See Installation Instructions for detailed
instructions.
FLUSH INSET INSTALLATION 3/4" PANELS
A