Specification Sheet
For questions about your
appliance, please call 1-800-626-2000.
Product Specication Created 10/19PAGE 10 OF 17
FLUSH INSET
INSTALLATION
HELPFUL TIPS
FLUSH INSTALLATION
ZIF360NHLH_RH
ZIR360NHLH_RH
39" (99.1) Flush inset width
37 1/2" (95.3)
Width between cleats
7"
(17.8)
7"
(17.8)
3/4" (1.9)
Width of side cleats
5 1/4" (13.3)
1/2" (1.3)
26 3/16" (66.5)
Flush inset depth
20 15/16" (53.2)
Depth to cleat
FRONT VIEWSIDE VIEW
TOP VIEW
3 1/2"
(8.9)
W
Finished cleats
Finished cleats
Case Trim
3/4" Panel
Case
Door
5 1/2"
(14.0)
24 3/16"
(61.4)
9"
(22.9)
ELEC.
3 1/2"
(8.9)
75 1/2"
(191.8 )
From floor
to bottom
of electrical
area
WATER
3 1/2"
(9.0)
85"
(215.9)
85"
(215.9)
C
B
ANTI-TIP BRACKET
SIDE VIEW
W
25 3/8" (64.5)
1 1/2"
(3.8)
7/16"
(1.1)
Trim overlap
3 1/2"
(8.9)
FRONT VIEW
ELEC.
35 1/2" (90.2)
2 5/16"
(5.9)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75
1/2
"
(191.8)
From floor
to bottom
of electrical
area
5 1/2"
(14.0)
9"
(22.9)
ZIF360NXRH
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
5"
(12.7)
5"
(12.7)
WATER
3 1/2"
(9.0)
81 1/2"
(207.0)
Use two
additional hole
locations at
end of
brackets
Wall
Studs
Bracket
mounted
into vertical
wall studs
centered
within the
cutout
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
A
Mounting the junction box in this
location will also allow for front
accessibility through access panel.
B
Water supply area.
C
Top cleat should be 1" thick
WARNING:
e freezer is top heavy and must
be secured to prevent the possibility
of tipping forward. Failure to do so
may result in death or serious injury.
e information below is for
cabinet design only. When installing
the anti-tip system you must use the
product installation instructions.
e information below applies to all
installation constructions:
• A wall bracket, bolts and toggles will
be supplied with the unit.
• e bolts will be used to attach
bracket to wall in 4 locations. Two
of the locations must penetrate the
center of the wall studs.
• e toggles are used for stability in
drywall and when metal studs are
encountered. Lag bolts are used in
wood studs.
• In installation opening, measure
81 1/2" from floor and draw a
horizontal line.
• Locate and mark the wall studs on
horizontal line. Verify at least two
studs have their centerlines within the
center 32 1/2" of installation opening
to ensure 2 wall studs are penetrated.
• e bracket will be centered left to
right in opening with bottom of
bracket on the horizontal line.
• When unit is placed in opening, the
bracket tabs will align with openings
in back of the unit. e unit will be
secured to the bracket using supplied
“L” bolts.
See Installation Instructions for detailed
instructions.
FLUSH INSET INSTALLATION 3/4" PANELS
A