Specifications
ZIF360NHLHMONOGRAM 36" BUILT-IN ALL-FREEZER
Product Specification Revised 1/18
NOTES
FLUSH INSTALLATION
ZIF360NHLH_RH
ZIR360NHLH_RH
39" (99.1) Flush inset width
37 1/2" (95.3)
Width between cleats
7"
(17.8)
7"
(17.8)
3/4" (1.9)
Width of side cleats
5 1/4" (13.3)
1/2" (1.3)
26 3/16" (66.5)
Flush inset depth
20 15/16" (53.2)
Depth to cleat
FRONT VIEWSIDE VIEW
TOP VIEW
3 1/2"
(8.9)
W
Finished cleats
Finished cleats
Case Trim
3/4" Panel
Case
Door
5 1/2"
(14.0)
24 3/16"
(61.4)
9"
(22.9)
ELEC.
3 1/2"
(8.9)
75 1/2"
(191.8 )
From floor
to bottom
of electrical
area
WATER
3 1/2"
(9.0)
85"
(215.9)
85"
(215.9)
C
B
ANTI-TIP BRACKET
24" (61.0)
1 1/2"
(3.8)
3"
(7.6)
7/16"
(1.1)
Trim overlap
35 1/2" (90.2)
2 5/16"
(5.9)
SIDE VIEWFRONT VIEW
ZIC360NXRH
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5 )
From floor
to bottom
of electrical
area
ELEC.
6"
(15.2)
10"
(25.4)
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
81 1/2"
(207.0)
WATER
5"
(12.7)
5"
(12.7)
3 1/2"
(9.0)
WATER
10"(25.4)
Use two
additional hole
locations at end
of brackets
Wall
Studs
Bracket
mounted
into vertical
wall studs
centered
within the
cutout
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
NOTES
A
Mounting the junction box in
this location will also allow
for front accessibility through
access panel.
B
Water supply area.
C
Top cleat should be 1" thick
WARNING:
The freezer is top heavy and
must be secured to prevent the
possibility of tipping forward.
Failure to do so may result in
death or serious injury.
The information below is for
cabinet design only. When
installing the anti-tip system you
must use the product installation
instructions.
The information below applies to
all installation constructions:
• A wall bracket, bolts and toggles
will be supplied with the unit.
• The bolts will be used to attach
bracket to wall in 4 locations.
Two of the locations must
penetrate the center of the wall
studs.
• The toggles are used for stability
in drywall and when metal studs
are encountered. Lag bolts are
used in wood studs.
• In installation opening, measure
81 1/2" from floor and draw a
horizontal line.
• Locate and mark the wall studs
on horizontal line. Verify at least
two studs have their centerlines
within the center 32 1/2" of
installation opening to ensure 2
wall studs are penetrated.
• The bracket will be centered left
to right in opening with bottom
of bracket on the horizontal line.
• When unit is placed in opening,
the bracket tabs will align with
openings in back of the unit.
The unit will be secured to the
bracket using supplied “L” bolts.
See Installation Instructions for
detailed instructions.
FLUSH INSET INSTALLATION 3/4" PANELS
FLUSH INSET
INSTALLATION