Installation Instructions
Design Guide
FOR MODELS ZIDI240 AND ZIDS240
THE INSTALLATION SPACE
IMPORTANT: Double-Drawer Refrigerators are
designed to be built-in only. They cannot be used
free-standing. The cutout dimensions allow for full
drawer extension.
Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall as shown. Electrical must
be located on rear wall as shown.
• NOTE: GFCI (ground fault circuit interrupter) is not
recommended.
• Products must operate from separate, properly
grounded receptacles.
Black or Stainless Steel Toekick Options
• These products are shipped with a stainless steel
toekick and a black toekick. For shipping purposes, one
of the toe kicks will be secured to the back of the unit,
and the second will be installed on the unit. Keep the
unused toekick and any unused parts for future use.
Single Product Installation:
For a flush installation ZIDS240 models only
,QVWDOOWKHSURGXFWVRWKHIURQWIDFHZLOOEHÀXVKZLWKWKH
adjacent cabinets.
For a standard installation
The product must be installed so the front face will
project forward of the adjacent cabinets and align to
custom cabinet fronts. The distance forward from the
adjacent cabinet is typically between the dimensions
shown. The opening between cabinets must be a
minimum of dimension K.
SIDE-BY-SIDE INSTALLATIONS
For a complete refreshment center, Install a fresh
food refrigerator beside a Double-Drawer refrigerator,
Beverage Center, or Wine Chiller/Wine Reserve.
• A side by side installation requires minimum width
openings depending on if the product will be flush or
standard mounted and if there are stainless or custom
panels. See chart below.
NOTE: In addition to this manual, reference the
installation manual of other appliance to ensure
product alignment, allow full door swing, and prevent
interference with adjacent cabinetry. Adjacent product
door hinge should be located away from the Double-
Drawer product to minimize interference.
For a flush installation ZIDS240 model only
Install the product so the front face is flush with the
adjacent cabinets and adjacent appliance. See chart for
minimum cut out width M.
For a standard installation
The product must be installed so the front face will
project forward of the adjacent cabinets and align to
custom cabinet fronts and adjacent appliance. The
distance forward from the adjacent cabinet is typically
between the dimensions shown. The opening between
cabinets must be a minimum of dimension L.
Panel Mount Depth Style
Minimum width
Opening
Stainless Flush M
Stainless Standard L
Custom Standard (only) L
Flush
Installation
Front edge of product case
Front face
CABINET CABINET
6 31-1000643
Standard
Installation
Front edge of product case
Front face
CABINET CABINET
1-5/8” to 2-5/8”