Spec Sheet

PAGE 13 OF 17
For questions about your 
appliance, please call 1-800-626-2000.
Product Specication Created 10/19
FLUSH INSET INSTALLATION
HELPFUL TIPS
A
  Mounting the junction box in 
this location will also allow for 
front accessibility through 
access panel.
B
 Water supply area.
 WARNING:
e refrigerator is top heavy and 
must be secured to prevent the 
possibility of tipping forward. 
Failure to do so may result in death 
or serious injury.
e information below is for cabinet 
design only. When installing the 
anti-tip system you must use the 
product installation instructions.
e information below applies to 
all installation constructions:
• A wall bracket, bolts and toggles will 
be supplied with the unit.
• e bolts will be used to attach 
bracket to wall in 4 locations. Two 
of the locations must penetrate the 
center of the wall studs.
• e toggles are used for stability in 
drywall and when metal studs are 
encountered. Lag bolts are used in 
wood studs.
• In installation opening, measure 
82" from floor and draw a horizontal 
line.
• Locate and mark the wall studs on 
horizontal line. Verify at least two 
studs have their centerlines within 
the center 32-1/2" of installation 
opening to ensure 2 wall studs are 
penetrated.
• e bracket will be centered left 
to right in opening with bottom of 
bracket on the horizontal line.
• When unit is placed in opening, the 
bracket tabs will align with openings 
in back of the unit. e unit will be 
secured to the bracket using supplied 
“L” bolts.
See Installation Instructions for 
detailed instructions.
FLUSH INSTALLATION
ZIC360NHLH_RH
39" (99.1) Flush inset width
37 1/2" (95.3)
Width between cleats
3/4" (1.9)
Width of side cleats
5 3/8" (13.7)
1/2" (1.3)
26 3/16" (66.5)
Flush inset depth
20 13/16" (52.9)
Depth to cleat
FRONT VIEWSIDE VIEW
TOP VIEW
3 1/2"
(8.9)
W
Finished cleats
Finished cleats
Case Trim
1/2" Panel
Case
Door
6"
(15.2)
24 3/16"
(61.4)
7"
(17.8)
7"
(17.8)
10"
(25.4)
3 1/2"
(8.9)
75 1/2"
(191.8 )
From floor
to bottom
of electrical
area
ELEC.
84"
(213.4)
height
to cleat
85" 
(215.9)
WATER
3 1/2"
(9.0)
FLUSH INSET INSTALLATION 1/2" PANELS
A
B
ANTI-TIP BRACKET
FLUSH INSET KIT ZKFN REQUIRED
ZIC360NXRH
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
81 1/2"
(207.0)
Use two 
additional hole 
locations at end 
of brackets
Wall
Studs
Bracket 
mounted
into vertical 
wall studs
centered
within the
cutout
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET