Quick Specification
PAGE 10 OF 17 Product Specication Revised 2/20
For questions about your
appliance, please call 1-800-626-2000.
FLUSH INSET INSTALLATION
HELPFUL TIPS
A
Mounting the junction box in this
location will also allow for front
accessibility through access panel.
B
Water supply area.
WARNING:
e refrigerator is top heavy and must be
secured to prevent the possibility of tipping
forward. Failure to do so may result in
death or serious injury.
e information below is for cabinet design
only. When installing the anti-tip system
you must use the product installation
instructions.
e information below applies to all
installation constructions:
• A wall bracket, bolts and toggles will be
supplied with the unit.
• e bolts will be used to attach bracket to
wall in 4 locations. Two of the locations
must penetrate the center of the wall studs.
• e toggles are used for stability in drywall
and when metal studs are encountered. Lag
bolts are used in wood studs.
• In installation opening, measure 82" from
floor and draw a horizontal line.
• Locate and mark the wall studs on
horizontal line. Verify at least two studs
have their centerlines within the center
32-1/2" of installation opening to ensure
2 wall studs are penetrated.
• e bracket will be centered left to right
in opening with bottom of bracket on the
horizontal line.
• When unit is placed in opening, the bracket
tabs will align with openings in back of the
unit. e unit will be secured to the bracket
using supplied “L” bolts.
See Installation Instructions for detailed
instructions.
FLUSH INSTALLATION
ZIC360NHLH_RH
39" (99.1) Flush inset width
37 1/2" (95.3)
Width between cleats
3/4" (1.9)
Width of side cleats
5 1/4" (13.3)
1/2" (1.3)
26 3/16" (66.5)
Flush inset depth
20 15/16" (53.2)
Depth to cleat
FRONT VIEWSIDE VIEW
TOP VIEW
3 1/2"
(8.9)
W
Finished cleats
Finished cleats
Case Trim
3/4" Panel
Case
Door
6"
(15.2)
24 3/16"
(61.4)
7"
(17.8)
7"
(17.8)
10"
(25.4)
3 1/2"
(8.9)
75 1/2"
(191.8 )
From floor
to bottom
of electrical
area
ELEC.
84"
(213.4)
height
to cleat
85"
(215.9)
WATER
3 1/2"
(9.0)
FLUSH INSET INSTALLATION 3/4" PANELS
A
B
ANTI-TIP BRACKET
FLUSH INSET KIT ZKFN REQUIRED
ZIC360NXRH
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
81 1/2"
(207.0)
Use two
additional hole
locations at end
of brackets
Wall
Studs
Bracket
mounted
into vertical
wall studs
centered
within the
cutout
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
WARNING:
Door Trim Pinch Point Hazard
Improper installation can lead to a finger
pinch point hazard between the side door
trim and the cabinets when operating the
door, especially with children. To minimize
this risk you must follow the installation
instructions for cabinet dimensions, trim
assembly and door stop angle.