Quick Specs

ZIC360NHRHMONOGRAM
36" BUILT-IN BOTTOM-FREEZER REFRIGERATOR
Product Specification Revised 1/18
A
Mounting the junction box in
this location will also allow for
front accessibility through
access panel.
B
Water supply area.
WARNING:
The refrigerator is top heavy and
must be secured to prevent the
possibility of tipping forward. Failure
to do so may result in death or
serious injury.
The information below is for cabinet
design only. When installing the
anti-tip system you must use the
product installation instructions.
The information below applies to all
installation constructions:
A wall bracket, bolts and toggles
will be supplied with the unit.
The bolts will be used to attach
bracket to wall in 4 locations. Two
of the locations must penetrate
the center of the wall studs.
The toggles are used for stability
in drywall and when metal studs
are encountered. Lag bolts are
used in wood studs.
In installation opening, measure
82" from floor and draw a
horizontal line.
Locate and mark the wall studs on
horizontal line. Verify at least two
studs have their centerlines within
the center 32-1/2" of installation
opening to ensure 2 wall studs are
penetrated.
The bracket will be centered left
to right in opening with bottom of
bracket on the horizontal line.
When unit is placed in opening,
the bracket tabs will align with
openings in back of the unit. The
unit will be secured to the bracket
using supplied “L” bolts.
See Installation Instructions for
detailed instructions.
FLUSH INSTALLATION
ZIC360NHLH_RH
39" (99.1) Flush inset width
37 1/2" (95.3)
Width between cleats
3/4" (1.9)
Width of side cleats
5 1/4" (13.3)
1/2" (1.3)
26 3/16" (66.5)
Flush inset depth
20 15/16" (53.2)
Depth to cleat
FRONT VIEWSIDE VIEW
TOP VIEW
3 1/2"
(8.9)
W
Finished cleats
Finished cleats
Case Trim
3/4" Panel
Case
Door
6"
(15.2)
24 3/16"
(61.4)
7"
(17.8)
7"
(17.8)
10"
(25.4)
3 1/2"
(8.9)
75 1/2"
(191.8 )
From floor
to bottom
of electrical
area
ELEC.
84"
(213.4)
height
to cleat
85"
(215.9)
WATER
3 1/2"
(9.0)
NOTES
FLUSH INSET INSTALLATION 3/4" PANELS
A
B
ANTI-TIP BRACKET
24" (61.0)
1 1/2"
(3.8)
3"
(7.6)
7/16"
(1.1)
Trim overlap
35 1/2" (90.2)
2 5/16"
(5.9)
SIDE VIEWFRONT VIEW
ZIC360NXRH
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5 )
From floor
to bottom
of electrical
area
ELEC.
6"
(15.2)
10"
(25.4)
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
81 1/2"
(207.0)
WATER
5"
(12.7)
5"
(12.7)
3 1/2"
(9.0)
WATER
10"(25.4)
Use two
additional hole
locations at end
of brackets
Wall
Studs
Bracket
mounted
into vertical
wall studs
centered
within the
cutout
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
FLUSH INSET
INSTALLATION