Installation Instructions

THE INSTALLATION SPACE
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 26-3/16” (66.52 cm)
Wooden cleats are required for flush installation. See
Side Cleats on page 27.
Cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot
exceed the 26-3/16” (66.52 cm) installation depth
shown. The top case trim overlaps the bottom of the
soffit.
Additional Specifications
A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be located
on rear wall as shown.
Water line can enter the opening through the floor
or back wall. Route SmartConnect
kit or 1/4” O.D.
copper tubing between the cold water line and the
water connection location. The tubing should be
long enough to extend to the front of the refrigerator.
Installation of an easily accessible shut-off valve in
the water line is required.
DIMENSIONS AND CLEARANCES
Product Clearances
These refrigerators are equipped with a 3-position door
stop. The factory set 115° door swing can be adjusted
to 90° if clearance to adjacent cabinets or walls is
restricted.
For a 90 degree door swing, allow 4” (10.16 cm) min.
clearance to wall. If the 90 degree door stop position
is used, pan access is maintained, but pan removal is
restricted
36" Frame to
Frame Width
As Shipped
*84" From
Floor to
Top Frame
35"
Case Width
*83-1/2"
at
Rear
25-3/8"
Case Depth
Depth Including
Handles 26-7/8"
* Shipping height. The
refrigerator can be
adjusted to fit into a cutout
that is 85” (215.9 cm) max.
height. Use leveling legs
and wheels for a maximum
1” (2.54 cm) height
adjustment.
22
6"
Wall View
Electrical
Area
85"
Finished
Opening
75-1/2" From
Floor to
Bottom
of Electrical Area
10"
26-3/16" Cutout
Depth
39"
Finished Width
4-5/16"
7"
3-1/2"
3-1/2"
3-1/2" 3-1/2"
7"
3-1/2"
Water Supply
Design Guide - Flush Installation
*Min. Distance to Wall: 4"
38-3/4"
90°
90° Door Swing
20-5/8"
Behind
Frame
115° Door Swing
CUSTOM HANDLE DESIGN GUIDE
Custom handles must be used for flush installation. For
custom handle installation, counterbore holes in rear of
decorative panels must ensure 1/2” (1.27 cm) material
thickness remains for handle support.
NOTE: The counterbore must not exceed 1” in diameter.
Minimum distance on Fresh Food
Door from handle side edge to
handle center should be 3-1/2”
(8.89 cm) as shown.
Minimum distance on Freezer Door
from top edge to handle center on
the freezer drawer
should be 1-1/2”
(2.54 cm)as
shown.
1/4”
1/2”
3/4”
7/8"
0.85"
1/2"
3-1/2”
1-1/2”
31-49142-1