Installation Instructions

STEP 2 INSTALL WATER LINE
WARNING
Connect to potable water supply
only.
AVERTISSEMENT
Raccordez l’appareil à une
alimentation d’eau potable seulement.
A cold water supply is required for automatic icemaker
operation. The water pressure must be between 40 and
120 p.s.i. (275-827 kPa).
Route 1/4” OD copper or SmartConnect
plastic
tubing between house cold water line and the water
connection location.
Tubing should be long enough to extend to the front of
the refrigerator. Allow enough tubing to accommodate
bend leading into the water line connection.
NOTE: The only Monogram-approved plastic tubing is
supplied in the SmartConnect
Refrigerator Tubing kits.
Do not use any other plastic water supply line because
the line is under pressure at all times. Other types of
plastic may crack or rupture with age and cause water
damage to your home.
SmartConnect
Refrigerator Tubing Kits are available in
the following lengths:
2 (.6 m) WX08X10002
8 (2.4 m) WX08X10006
15’ (4.6 m) WX08X1 0015
25’ (7.6 m) WX08X10025
Shut off the main water supply.
Turn on the nearest faucet long enough to clear the line
of water.
Install a shut-off valve between the icemaker water
valve and cold water pipe in a basement or cabinet.
The shut-off valve should be located where it will be
easily accessible.
Turn on the main water supply and flush debris.
Run about a quart of water through the tubing into
a bucket. Shut off water supply at the shut-off valve.
NOTE: Saddle type shut-off valves are included in
many water supply kits, but are not recommended
for this application.
STEP 1 REMOVE PACKAGING
WARNING
Tip Over Hazard.
The refrigerator is much heavier at the top than at the
bottom—be careful when moving. When using a hand
truck, handle from the side only.
AVERTISSEMENT
Risque de
basculement Le réfrigérateur est beaucoup plus
lourd en haut qu’en bas. Il faut être prudent lors des
déplacements. Si un diable est utilisé, il faut soulever le
réfrigérateur sur le côté seulement.
Carefully cut banding at the top and bottom, remove the
outer carton.
Slide out the back corner posts (2).
Slide the carton off the top of the cabinet.
NOTE: IT IS NOT NECESSARY TO LAY THE CABINET
DOWN IN ORDER TO REMOVE THE SKID!
The unit is secured to the
skid with 4 slotted tie-down
straps. Remove the six 7/16”
bolts from the base channels
in the tie-downs.
Remove the six 7/16” bolts
securing the straps to the
skid.
NOTE: DO NOT ATTEMPT
TO ROLL UNIT OFF SKID.
The support blocks on the
bottom of the refrigeration
case must be removed before
the refrigerator is taken off the skid or damage will
occur. Carefully tilt the refrigerator and slide the blocks
out from beneath.
Remove the toekick and set aside for final installation.
Lift the refrigerator off the skid with an appliance dolly.
Handle from the sides.
12
Floor
Waterline Tubing
Installation Instructions - Standard Installation
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
Remove 2 strap
bolts on each side
Remove 5
base channel
bolts on each
side
31-49142-1