Quick Specs
A
 Mounting the junction box in 
this location will also allow for 
front accessibility through 
access panel.
B
 Water supply area.
 WARNING:
The refrigerator is top heavy and 
must be secured to prevent the 
possibility of tipping forward. Failure 
to do so may result in death or 
serious injury.
The information below is for cabinet 
design only. When installing the 
anti-tip system you must use the 
product installation instructions.
The information below applies to 
all installation constructions:
• A wall bracket, bolts and toggles 
will be supplied with the unit.
• The bolts will be used to attach 
bracket to wall in 4 locations. Two 
of the locations must penetrate 
the center of the wall studs.
• The toggles are used for stability 
in drywall and when metal studs 
are encountered. Lag bolts are 
used in wood studs.
• In installation opening, measure 
82" from floor and draw a 
horizontal line.
• Locate and mark the wall studs on 
horizontal line. Verify at least two 
studs have their centerlines within 
the center 32-1/2" of installation 
opening to ensure 2 wall studs are 
penetrated.
• The bracket will be centered left 
to right in opening with bottom of 
bracket on the horizontal line.
• When unit is placed in opening, 
the bracket tabs will align with 
openings in back of the unit. The 
unit will be secured to the bracket 
using supplied “L” bolts.
See Installation Instructions for 
detailed instructions.
FLUSH INSTALLATION
ZIC360NHLH_RH
39" (99.1) Flush inset width
37 1/2" (95.3)
Width between cleats
3/4" (1.9)
Width of side cleats
5 3/8" (13.7)
1/2" (1.3)
26 3/16" (66.5)
Flush inset depth
20 13/16" (52.9)
Depth to cleat
FRONT VIEWSIDE VIEW
TOP VIEW
3 1/2"
(8.9)
W
Finished cleats
Finished cleats
Case Trim
1/2" Panel
Case
Door
6"
(15.2)
24 3/16"
(61.4)
7"
(17.8)
7"
(17.8)
10"
(25.4)
3 1/2"
(8.9)
75 1/2"
(191.8 )
From floor
to bottom
of electrical
area
ELEC.
84"
(213.4)
height
to cleat
85" 
(215.9)
WATER
3 1/2"
(9.0)
FLUSH INSET INSTALLATION 1/2" PANELS
A
B
ANTI-TIP BRACKET
24" (61.0)
1 1/2"
(3.8)
3"
(7.6)
7/16"
 (1.1)
Trim overlap
35 1/2" (90.2)
2 5/16"
(5.9)
SIDE VIEWFRONT VIEW
ZIC360NXRH
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5 )
From floor
to bottom
of electrical
area
ELEC.
6"
(15.2)
10"
(25.4)
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
81 1/2"
(207.0)
WATER
5"
(12.7)
5"
(12.7)
3 1/2"
(9.0)
WATER
10"(25.4)
Use two 
additional hole 
locations at end 
of brackets
Wall
Studs
Bracket 
mounted
into vertical 
wall studs
centered
within the
cutout
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
ZIC360NHLHMONOGRAM 36" BUILT-IN BOTTOM-FREEZER REFRIGERATOR
NOTES
FLUSH INSET 
INSTALLATION
Product Specification Revised 1/18