CUTOUT INSTALLATION
SIDE VIEW
INSTALLATION CUTOUT
FRONT VIEW
ELECTRIC/
WATER
10 1/2" (26.7)
1 1/2" (3.8)
34 1/2"
(87.6) min
underside of
counter to floor
35" (88.9) max
24" (61.0)
min cutout depth
23 3/4" (60.3)
min standard
24" (61.0)
min flush inset
9"
(22.9) max
ZIBS240PSS
CUTOUT INSTALLATION
SIDE VIEW
INSTALLATION CUTOUT
FRONT VIEW
ELECTRIC/
WATER
10 1/2" (26.7)
1 1/2" (3.8)
34 1/2"
(87.6) min
underside of
counter to floor
35" (88.9) max
24" (61.0)
min cutout depth
23 3/4" (60.3)
min standard
24" (61.0)
min flush inset
9"
(22.9) max
ZIBS240PSS
CABINET CABINET
Dim. A
Front Edge of
Product Case
Front Face
Standard
Installation
110º
120º
In a standard installation, the
product will project forward of
adjacent cabinets. See Dim. A.
23 3/4" min.
CABINET CABINET
These products will fit flush to adjacent
cabinets when installed with a Dim. A - width
filler panel or cleat. The filler panel should be
recessed or set back behind the door and
even with the front edge of the product case.
110º
120º
Flush
Installation
Filler panel or cleat to be set
back even with front of case.
Front Edge of
Product Case
Dim. A
Front Face
24" min. width
stainless steel models
PRODUCT DIM. A
ZDWI240, ZDB1240 1"
ZDWR240, ZDBR240 1"
ZIB1240, ZIF1240 1"
ZIFS240, ZIBS240 1/4"
ZDOD240 1-1/4"
PRODUCT DIM. A
ZDWI240, ZDB1240 2"
ZDWR240, ZDBR240 1-3/4"
ZIFS240, ZIF1240 1-5/8"
ZDOD240 1-7/8"
ZIB1240, ZIBS240 2-5/8"
REFRIGERATION MODULES, TOP VIEW
INSTALLATION NOTES
Installation Space
is module can be installed
beneath a countertop or can be
used free-standing.
For a standard installation of
stainless steel unit: e product
must be installed so that the front
face will project 2-5/8" forward of
adjacent cabinets.
For a flush installation of stainless
steel unit: Install a 1" wide filler strip
on the hinge side. e width of the
opening must be 24" min. wide. See
installation instructions for details.
Location Requirements: All
Monogram Refrigeration Modules
may be closed in on the top and sides
as long as the front is unobstructed
for air circulation and door swing.
Do not install these products where
the temperatures will go below 55° F
(13 C) or above 90° F (32 C).
Products must operate from separate
properly grounded receptacles.
ese products are not designed to
be stacked one over the other.
See installation instructions for
side-by-side information.
INSTALLATION CUTOUT
SIDE VIEW
INSTALLATION CUTOUT
FRONT VIEW