PAGE 3 OF 5 Product Specication Created 12/20
HELPFUL TIPS
INSTALLATION
3"
(7.6) min
19 1/8" (48.6) min
19 1/4" (48.9) max
Cutout depth
5"
(12.7) min
16" (40.6) min
To electrical junction box
Locate electrical junction box
at least
16" below the countertop
15"
(38.1)
min
13"
(33.0) max
33 7/8" (86.0) min
34" (86.3) max
Cutout width
1 3/4" (4.5) min
Clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
2 1/2" (6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
36 " (91.4)
Cabinet base
SIDE VIEWFRONT VIEW
TOP VIEW OF CUTOUT SIDE VIEW
DRAWER
FRONT
ZHU36RSJSS
3"
(7.6) min
19 1/8" (48.6) min
19 1/4" (48.9) max
Cutout depth
5"
(12.7) min
16" (40.6) min
To electrical junction box
Locate electrical junction box
at least
16" below the countertop
15"
(38.1)
min
13"
(33.0) max
33 7/8" (86.0) min
34" (86.3) max
Cutout width
1 3/4" (4.5) min
Clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
2 1/2" (6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
36 " (91.4)
Cabinet base
SIDE VIEWFRONT VIEW
TOP VIEW OF CUTOUT SIDE VIEW
DRAWER
FRONT
ZHU36RSJSS
A
Wall coverings, countertop and cabinets
surrounding cooktop must be able to
withstand temperatures of up to 200ºF.
B
Minimum 30" clearance from countertop
to unprotected overhead surfaces, when
no ventilation hood or microwave oven is
installed.
C
When using a ventilation hood or
microwave oven above the cooktop, see
hood or microwave installation instructions
for minimum overhead clearance
dimensions.
D
Minimum 15" of clearance from countertop
to nearest overhead surface on both sides of
cooktop. Make sure to include any lighting
rail covers in calculation.
E
Minimum 2" distance from edge of cutout
to nearest adjacent side wall below upper
cabinets.
F
Install an approved junction box where it
can be easily reached through the front of
the cabinet where the cooktop is located.
IMPORTANT: For serviceability, the
junction box must be located where it will
allow considerable slack in the 48" long
conduit.
G
Maximum 13" depth of unprotected
overhead surfaces, when no ventilation
hood or microwave oven is installed.
H
For Americans with Disabilities Act (ADA)
forward approach installation: Minimum 5"
clearance between the top of the countertop
and the enclosure. e enclosure must be
made of at least 1/4" thick wood material,
and must have an access panel installed in
order to provide access to the junction box
and hold-down brackets, and to allow for
service of the cooktop.
For more details refer to the installation
instructions for this product.
COUNTERTOP CUT-OUT
DIMENSIONS
ADA INSTALLATION
Dimensions in parentheses are in centimeters unless otherwise noted.
B
A
C
D
H
E
G
F