Quick Specification
For questions about your
appliance, please call 1-800-626-2000.
PAGE 3 OF 5 Product Specication Created 12/20
HELPFUL TIPS
INSTALLATION
19 5/8" (49.9) min
19 3/4" (50.2) max
Cutout depth
5"
(12.7) min
3"
(7.6) min
16" (40.6) min
To electrical junction box
Locate electrical junction box
at least
16" below the countertop
15"
(38.1)
min
28 1/2" (72.4) min
28 5/8" (72.7) max
Cutout width
1 3/4" (4.5) min
Clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
2 1/2" (6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
30 " (76.2)
Cabinet base
SIDE VIEWFRONT VIEW
TOP VIEW OF CUTOUT SIDE VIEW
DRAWER
FRONT
ZHU30RSJSS
13"
(33.0) max
19 5/8" (49.9) min
19 3/4" (50.2) max
Cutout depth
5"
(12.7) min
3"
(7.6) min
16" (40.6) min
To electrical junction box
Locate electrical junction box
at least
16" below the countertop
15"
(38.1)
min
28 1/2" (72.4) min
28 5/8" (72.7) max
Cutout width
1 3/4" (4.5) min
Clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
2 1/2" (6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
30 " (76.2)
Cabinet base
SIDE VIEWFRONT VIEW
TOP VIEW OF CUTOUT SIDE VIEW
DRAWER
FRONT
ZHU30RSJSS
13"
(33.0) max
COUNTERTOP CUT-OUT DIMENSIONS
ADA INSTALLATION
Dimensions in parentheses are in centimeters unless otherwise noted.
A
B
C
D
E
H
F
G
A
Wall coverings, countertop and cabinets
surrounding cooktop must be able to
withstand temperatures of up to 200ºF.
B
Minimum 30" clearance from countertop
to unprotected overhead surfaces,
when no ventilation hood or microwave
oven is installed.
C
When using a ventilation hood or
microwave oven above the cooktop,
see hood or microwave installation
instructions for minimum overhead
clearance dimensions.
D
Minimum 15" of clearance from
countertop to nearest overhead surface
on both sides of cooktop. Make sure
to include any lighting rail covers in
calculation.
E
Minimum 2" distance from edge of cutout
to nearest adjacent side wall below
upper cabinets.
F
Install an approved junction box where it
can be easily reached through the front of
the cabinet where the cooktop is located.
IMPORTANT: For serviceability, the
junction box must be located where it
will allow considerable slack in the 48"
long conduit.
G
Maximum 13" depth of unprotected
overhead surfaces, when no ventilation
hood or microwave oven is installed.
H
For Americans with Disabilities Act
(ADA) forward approach installation:
Minimum 5" clearance between the top
of the countertop and the enclosure. e
enclosure must be made of at least 1/4"
thick wood material, and must have an
access panel installed in order to provide
access to the junction box and hold-down
brackets, and to allow for service of the
cooktop.
For more details refer to the installation
instructions for this product.