Quick Specs

For questions about your
appliance, please call 1-800-626-2000.
PAGE 5 OF 5 Product Specication Created 12/20
HELPFUL TIPS
FLUSH MOUNT INSTALLATION
Countertop
ELEC.
Wall Oven
4 3/4"
(12.1) max
R 5/8" (1.6)
All Four Corners
3/4" (1.9)
Width of rabbet
in countertop
1/4" (0.6) max
Depth of rabbet
in countertop
21 1/8"
(53.7)
30" (76.2)
5 1/2"
(14.0) min
FRONT VIEW
X X
SIDE VIEW SIDE VIEW
ZHU30RSJSS
31 1/4"
(79.4) min
From top
surface of
countertop
to top
surface of
wall oven
platform
Countertop
ELEC.
Wall Oven
4 3/4"
(12.1) max
R 5/8" (1.6)
All Four Corners
3/4" (1.9)
Width of rabbet
in countertop
1/4" (0.6) max
Depth of rabbet
in countertop
21 1/8"
(53.7)
30" (76.2)
5 1/2"
(14.0) min
FRONT VIEW
X X
SIDE VIEW SIDE VIEW
ZHU30RSJSS
31 1/4"
(79.4) min
From top
surface of
countertop
to top
surface of
wall oven
platform
B
A
Use optional JXFLUSH1 kit to
flush-mount the cooktop into the
countertop. Read all installation
instructions supplied with cooktop
and kit before beginning installation.
B
To avoid hot cookware from
contacting the countertop surface,
the cooktop should be installed
at least 1/32" higher than the
countertop.
C
Use strips of wood or solid-surface
countertop material to reinforce the
countertop below the flush-mount
rabbet. For an island or peninsular
installation secure strips to all four
sides, otherwise just secure strips to
the front and back under the cutout.
D
Note this cooktop is only approved
for installation above specific wall
ovens as labeled on this unit.
E
When installing this cooktop above
a single wall oven, do not install the
baffle.
F
When this cooktop is installed above
a flush-mounted wall oven, the
clearance from the front edge of the
countertop to the front edge of the
cooktop cutout is minimum 2-1/2"
plus the wall oven cleat setback.
G
e cooktop platform must be a
minimum height of 4-3/4" from the
floor to ensure that the handle does
not hit the floor when the door is
opened.
H
Warming drawers are approved
for installation below only certain
specified cooktop models. See the
label attached to the top of the
warming drawer or underside of the
cooktop for approved combinations.
I
When installing the cooktop above
a warming drawer, a solid barrier
must be installed at least 5-1/2" from
the top of the countertop. Use any
solid material such as 1/4" thick
plywood. Allow at least 1/4" air gap
between the barrier and the top of
the warming drawer.
For more details refer to the installation
instructions for this product
FLUSH-MOUNT INSTALLATION
ABOVE WALL OVEN
FLUSH-MOUNT INSTALLATION
ABOVE WARMING DRAWER
For more details, refer to the installation instructions for this product on Monogram.com.
Dimensions in parentheses are in centimeters unless otherwise noted.
I
D
H
E
G
C
A
F
TOP VIEW OF CUTOUT SECTION X–X
Through countertop showing
depth of rabbet for flush-mount