Quick Specification
For questions about your
appliance, please call 1-800-626-2000.
HELPFUL TIPS
PAGE 3 OF 5 Product Specication Created 12/20
INSTALLATION
19 5/8" (49.9) min
19 3/4" (50.2) max
Cutout depth
5"
(12.7) min
3"
(7.6) min
16" (40.6) min
To electrical junction box
Locate electrical junction box
at least
16" below the countertop
15"
(38.1)
min
28 1/2" (72.4) min
28 5/8" (72.7) max
Cutout width
1 3/4" (4.5) min
Clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
2 1/2" (6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
30 " (76.2)
Cabinet base
SIDE VIEWFRONT VIEW
TOP VIEW OF CUTOUT SIDE VIEW
DRAWER
FRONT
ZHU30RSJSS
13"
(33.0) max
19 5/8" (49.9) min
19 3/4" (50.2) max
Cutout depth
5"
(12.7) min
3"
(7.6) min
16" (40.6) min
To electrical junction box
Locate electrical junction box
at least
16" below the countertop
15"
(38.1)
min
28 1/2" (72.4) min
28 5/8" (72.7) max
Cutout width
1 3/4" (4.5) min
Clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
2 1/2" (6.4) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
30 " (76.2)
Cabinet base
SIDE VIEWFRONT VIEW
TOP VIEW OF CUTOUT SIDE VIEW
DRAWER
FRONT
ZHU30RSJSS
13"
(33.0) max
COUNTERTOP CUT-OUT DIMENSIONS ADA INSTALLATION
Dimensions in parentheses are in centimeters unless otherwise noted.
A
B
C
D
E
H
F
G
A
Wall coverings, countertop and cabinets
surrounding cooktop must be able to
withstand temperatures of
up to 200ºF.
B
Minimum 30" clearance from countertop
to unprotected overhead surfaces, when
no ventilation hood or microwave oven is
installed.
C
When using a ventilation hood or microwave
oven above the cooktop, see hood or
microwave installation instructions for
minimum overhead clearance dimensions.
D
Minimum 15" of clearance from countertop
to nearest overhead surface on both sides of
cooktop. Make sure to include any lighting
rail covers in calculation.
E
Minimum 2" distance from edge of cutout to
nearest adjacent side wall below
upper cabinets.
F
Install an approved junction box where it
can be easily reached through the front of
the cabinet where the cooktop is located.
IMPORTANT: For serviceability, the junction
box must be located where it will allow
considerable slack in the 48" long conduit.
G
Maximum 13" depth of unprotected overhead
surfaces, when no ventilation hood or
microwave oven is installed.
H
For Americans with Disabilities Act (ADA)
forward approach installation: Minimum 5"
clearance between the top of the countertop
and the enclosure. e enclosure must be
made of at least 1/4" thick wood material, and
must have an access panel installed in order
to provide access to the junction box and
hold-down brackets, and to allow for service
of the cooktop.
For more details refer to the installation
instructions for this product.
I