Specification Sheet

For questions about your
appliance, please call 1-800-626-2000.
PAGE 3 OF 4 Product Specication Revised 6/20
4 9/16"
(11.6)
19 1/8" (48.6)
Cutout depth
5"(12.7)
18"
(45.7)
min
7/16"
(1.1) min
14 3/4"
(37.5) max
drawer depth
(36" models only)
16"
(40.6) max
33 7/8" (86.0)
Cutout width
Min clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
1 1/2" (3.8) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
36 "(91.4)
Cabinet base
FRONT VIEW
SIDE VIEW
SIDE VIEW
REAR WALL
Gas
supply
line
TOP VIEW OF CUTOUT
DRAWER
FRONT
12"
(30.5)
Allow 5"
minimum
depth
between the
countertop
and an
enclosure
Rear Wall
Non-Combustible
Combustible
Min. Clearance From
Cutout to Rear Wall
3 3/8" (8.6)
4 3/8" (11.1)
ZGU36E_ZGU36R
4 9/16"
(11.6)
19 1/8" (48.6)
Cutout depth
5"(12.7)
18"
(45.7)
min
7/16"
(1.1) min
14 3/4"
(37.5) max
drawer depth
(36" models only)
16"
(40.6) max
33 7/8" (86.0)
Cutout width
Min clearance between the
rear edge of the cutout
and the nearest wall
behind the cooktop
1 1/2" (3.8) min
Clearance between the
front edge of the cutout
and the front edge of the
countertop
36 "(91.4)
Cabinet base
FRONT VIEW
SIDE VIEW
SIDE VIEW
REAR WALL
Gas
supply
line
TOP VIEW OF CUTOUT
DRAWER
FRONT
12"
(30.5)
Allow 5"
minimum
depth
between the
countertop
and an
enclosure
Rear Wall
Non-Combustible
Combustible
Min. Clearance From
Cutout to Rear Wall
3 3/8" (8.6)
4 3/8" (11.1)
ZGU36E_ZGU36R
COUNTERTOP CUT-OUT DIMENSIONS
ADA INSTALLATION
Dimensions in parentheses are in centimeters unless otherwise noted.
B
A
C
D
I
E
G
F
H
STANDARD INSTALLATION
HELPFUL TIPS
A
Wall coverings, countertop and
cabinets surrounding cooktop must
be able to withstand temperatures
of up to 200ºF.
B
Minimum 30" clearance from
countertop to unprotected overhead
surfaces, when no ventilation hood
or microwave oven is installed.
C
When using a ventilation hood or
microwave oven above the cooktop,
see hood or microwave installation
instructions for minimum overhead
clearance dimensions.
D
Minimum 18" of clearance from
countertop to nearest overhead
surface on both sides of cooktop.
Make sure to include any lighting
rail covers in calculation.
E
Minimum 12" distance from edge
of cutout to adjacent side wall
below upper cabinets.
F
Minimum 12" distance from of
countertop to electrical junction box.
Gas supply line must be 1" distance
from rear wall of cabinet.
G
Maximum 16" depth of unprotected
overhead surfaces, when no
ventilation hood or microwave
oven is installed.
H
Non-Combustible as defined in
the National Fuel Gas Code (ANSI
Z223.1 Current Edition). Clearances
from non-combustible materials
are not part of the ANSI Z21.1
scope and are not certified by UL.
Clearances less than 4 3/8" must be
approved by local codes and/or the
authority having jurisdiction.
I
For Americans with Disabilities
Act (ADA) forward approach
installation: Minimum 5" clearance
between the top of the countertop
and the enclosure. e enclosure
must be made of at least 1/4" thick
wood material, and must have an
access panel installed in order to
provide access to the junction box
and hold-down brackets, and to
allow for service of the cooktop.
For more details refer to the installation
instructions for this product.