Specification Sheet

For questions about your
appliance, please call 1-800-626-2000.
PAGE 3 OF 4 Product Specication Created 12/20
DIMENSIONS AND INSTALLATION
INFORMATION (IN INCHES)
HELPFUL TIPS
PRODUCT DIMENSIONS AND
CLEARANCE
A 36"- or 42"-wide professional vent hood
is recommended for installation over this
rangetop.
Clearances between rangetop and side wall
must be at least 12" on each side.
Allow 8" free space below the top surface of
countertop. Allow additional clearances below
the burner box to install the regulator and
make house gas supply connections. Use a 90°
elbow to route the gas connections and limit
interference with drawers or other cabinetry.
* e opening between a 4" high backsplash
must be 36" to allow the rangetop to slide back
against the wall.
* *As defined in the National Fuel Gas Code
(ANSI Z223.1/CSA B149.1, Current Edition).
Clearances from non-combustible materials
are not part of the ANSI Z21.1/CSA 1.1 scope
and are not certified by CSA. Clearances less
than 12” must be approved by local codes and/
or the authority having jurisdiction.
GAS PRESSURE REGULATOR
You must use the gas pressure regulator supplied
with this rangetop. For proper operations the
inlet pressure to the regulator should be as
follows:
Natural Gas:
Minimum pressure: 6” of Water Column
Maximum pressure: 13” of Water Column
Propane (LP) Gas:
Minimum pressure: 11” of Water Column
Maximum pressure: 13” of Water Column
See installation instructions for more details
WARNING
Installations without a hood require 48"
minimum to combustibles above the
rangetop. A custom hood installation with
exposed horizontal combustible surfaces
must have an "auto-on" feature. Refer to
hood installation instructions for specific
hood clearances. e surface of the entire
back wall above the countertop and below
the hood must be covered with a non-
combustible material such as metal,
ceramic tile, brick, marble or other stone.
UTILITY LOCATIONS
**As defined in the National Fuel Gas Code
(ANSI Z223.1/CSA B149.1, Current Edition).
Clearances from non-combustible materials
are not part of the ANSI Z21.1/CSA 1.1 scope
and are not certified by CSA. Clearances less
than 12” must be approved by local codes
and/or the authority having jurisdiction.
** As defined in the National Fuel Gas Code (ANSI Z223.1/CSA
B149.1, Current Edition). Clearances from non-combustible
materials are not part of the ANSI Z21.1/CSA 1.1 scope and are not
certified by CSA. Clearances less than 12” must be approved by local
codes and/or the authority having jurisdiction.