Specification Sheet

For questions about your
appliance, please call 1-800-626-2000.
PAGE 3 OF 4 Product Specication Revised 3/22
DIMENSIONS AND INSTALLATION
INFORMATION (IN INCHES)
HELPFUL TIPS
PRODUCT DIMENSIONS AND
CLEARANCE
A 36"- or 42"-wide professional vent hood
is recommended for installation over this
rangetop.
Clearances between rangetop and side wall
must be at least 12" on each side.
Allow 8" free space below the top surface
of countertop. Allow additional clearances
below the burner box to install the regulator
and make house gas supply connections. Use
a 90° elbow to route the gas connections
and limit interference with drawers or other
cabinetry.
* The opening between a 4" high backsplash
must be 36" to allow the rangetop to slide
back against the wall.
* *As dened in the National Fuel Gas Code
(ANSI Z223.1/CSA B149.1, Current
Edition). Clearances from non-combustible
materials are not part of the ANSI Z21.1/
CSA 1.1 scope and are not certied by CSA.
Clearances less than 12” must be approved
by local codes and/or the authority having
jurisdiction.
GAS PRESSURE REGULATOR
You must use the gas pressure regulator
supplied with this rangetop. For proper
operations the inlet pressure to the regulator
should be as follows:
Natural Gas:
Minimum pressure: 6” of Water Column
Maximum pressure: 13” of Water Column
Propane (LP) Gas:
Minimum pressure: 11” of Water Column
Maximum pressure: 13” of Water Column
See installation instructions for more details
WARNING
Installations without a hood require 48"
minimum to combustibles above the
rangetop. A custom hood installation with
exposed horizontal combustible surfaces
must have an "auto-on" feature. Refer to
hood installation instructions for specic
hood clearances. The surface of the entire
back wall above the countertop and below
the hood must be covered with a non-
combustible material such as metal,
ceramic tile, brick, marble or other stone.
UTILITY LOCATIONS
**As defined in the National Fuel Gas Code
(ANSI Z223.1/CSA B149.1, Current Edition).
Clearances from non-combustible materials
are not part of the ANSI Z21.1/CSA 1.1 scope
and are not certified by CSA. Clearances less
than 12” must be approved by local codes
and/or the authority having jurisdiction.
** As dened in the National Fuel Gas Code (ANSI Z223.1/CSA
B149.1, Current Edition). Clearances from non-combustible
materials are not part of the ANSI Z21.1/CSA 1.1 scope and
are not certied by CSA. Clearances less than 12” must be
approved by local codes and/or the authority having jurisdiction.