Quick Specifications
ZGP486NDNSS (NATURAL GAS)
ZGP486LDNSS (LIQUID PROPANE)
MONOGRAM 48" ALL-GAS PROFESSIONAL  
RANGE WITH 6 BURNERS AND GRIDDLE
DIMENSIONS AND INSTALLATION INFORMATION 
(IN INCHES) 
Product Specification Created 8/19
Professional ranges oer a number of choices in size and 
cooktop configurations. 
 All Professional Ranges are factory set for natural or liquid 
propane gas. The correct model should be ordered for 
the installation situation.
NOTE
Conversion kits are included with the range if the wrong 
gas type was ordered. High Altitude kit, WB28K10553 
for operation above 6,000 feet (for Natural and LP gas 
models), is also available. The kits must be installed by 
a qualified service technician at additional cost.
INSTALLATION INFORMATION
Before installing, consult installation instructions packed 
with product or online at Monogram.com for current 
dimensional data. 
A suitable overhead vent hood is required for imodels with 
a grill and is recommended for all other models.
ADVANCE PLANNING
Refer to dimensional drawings for appropriate placement 
and necessary clearances when planning the installation.
• Working areas adjacent to the range should have 
18" minimum clearance between countertop and 
cabinet bottom.
• Clearance between range and side wall or combustible 
material must be at least 12" on each side.
• Installation must conform with local codes. In the 
absence of local codes, the range must comply 
with the National Fuel Gas Code, ANSI Z223.1-1990.
47 7/8" width
28 1/4"
35 1/4"
to
36 3/4"
height
3 1/4"
to 4 3/4"
Toekick/leg
height
Depth
to front
of door
ADDITIONAL CLEARANCES:
Allow 12" minimum clearance to an adjacent wall
on each side.
Wo
rking areas adjacent to the rangetop should have
18" minimum clearance between countertop and 
the bottom of the wall cabinet.
Non-Combustible
Material
13"
max.
18"
min.
36" min.
48" minimum
to combustibles
12" minimum
each side
12" minimum
to adjacent wall
 WARNING
Installations without a hood require 48" minimum 
to combustibles. A custom hood installation with 
exposed horizontal combustible surfaces must 
have an Auto-On feature. Refer to hood installation 
instructions for specific hood clearances.
The surface of the entire back wall above the range 
and below the hood must be covered with a non-
combustible material such as metal, ceramic tile, 
brick, marble or other stone.