Dimensions And Installation Information
ZGP486NDNSS (NATURAL GAS)
ZGP486LDNSS (LIQUID PROPANE)
MONOGRAM 48" ALL-GAS PROFESSIONAL  
RANGE WITH 6 BURNERS AND GRIDDLE
DIMENSIONS AND INSTALLATION INFORMATION 
(IN INCHES) 
Product Specification Created 8/19
ELECTRICAL REQUIREMENTS
Ranges must be hooked up to a 120V, 60Hz properly 
grounded dedicated circuit protected by a 15-amp circuit 
breaker or time-delay fuse.
OPTIONAL BACKSPLASH ACCESSORIES
The range requires a 12" minimum clearance to a vertical 
combustible surface at the rear. A backsplash is required 
for installations with less than 12" clearance. The following 
backsplash accessories are available, or a custom, non-
combustible backsplash can be used.
ORDER ONE WITH A 48"-WIDE RANGE BACKSPLASH 
UX12B48PSS–12" backsplash
UXADJB48PSS– 30"-36"  adjustable-height
backsplash with warming shelf
SIDE VIEW WITH A BACKSPLASH
Locate gas and electric as shown
Universal Utility Locations
48"
2"
6 1/2"
8"
11" 21"
Gas/
Electric
3"
10-1/2"
1-1/2"
12"
28-1/4" to
Beveled 
Edge of Control
Panel Bullnose
27-1/2" to
Beveled Edge
- Maximum
Adjacent
Cabinet Depth
for
Flush
Installation
13/16"
30-36"
3-3/16"
Control Panel
Depth
28-1/4"
to Front of
Door
48-1/4"
with Oven Door
Open
30-7/8"
to Front of
Handle
35-1/4"
to
36-3/4"
7" Control
Panel Height
28-7/8"
to Front
Edge
Optional
Backsplash
Accessories
GAS SUPPLY
• The natural gas models are designed to operate at 
5" water column pressure. For proper operation, the 
pressure of the natural gas supplied to the regulator 
must be between 7" and 13" water column. 
• The LP models are designed to operate at 10" water 
column pressure. For proper operation, the pressure 
of the LP gas supplied to the regulator must be 
between 11" and 13" water column.
UTILITY LOCATIONS