Specifications

NOTES
MONOGRAM 30" BUILT-IN SINGLE OVEN ZET1SHSS
Product Specification Revised 5/19
30" (76.2) flush inset width
with
1/8" (0.3) reveals
30" (76.2)
1 5/16"
(3.3)
27 1/4"
(69.2)
32 1/2"
(82.6)
Recommended
cutout
location
from floor
Side cleat
Top cleat
Bottom cleat
5 1/4"
(13.3)
9 1/2"
(24.1)
28 1/2" (72.4)
cutout width
3/4"
(1.9)
Side cleats
1 1/16"
(2.7)
Top cleat
3/4"
(1.9)
5 1/4"
(13.3)
3
(7.6)
9 1/2"
(24.1)
28 1/2" (72.4)
min cutout width
23 1/2"
(59.7) min cutout depth
27 1/4"
(69.2)
31 1/4"
(79.4) min
24 13/16"
(63.0)
cutout depth
24 13/16" (63.0)
cutout depth
23 1/2"
(59.7)
min cutout depth
2 1/2"
(6.4)
Side cleats
depth
29"
(73.7)
Flush inset
height with
1/8" (0.3)
reveal at top,
1/4" (0.6)
reveal at
bottom
11/16" (1.7) Bottom cleat
(Extends full depth of cabinet)
TOP VIEW
STANDARD
INSTALLATION
FLUSH INSET
INSTALLATION
FLUSH INSET INSTALLATION
FRONT VIEW
STANDARD INSTALLATION
FRONT VIEW
STANDARD
INSTALLATION
FLUSH INSET
INSTALLATION
ZET1SHSS
ELEC.
ELEC.
30" (76.2) flush inset width
with
1/8" (0.3) reveals
30" (76.2)
1 5/16"
(3.3)
27 1/4"
(69.2)
32 1/2"
(82.6)
Recommended
cutout
location
from floor
Side cleat
Top cleat
Bottom cleat
5 1/4"
(13.3)
9 1/2"
(24.1)
28 1/2" (72.4)
cutout width
3/4"
(1.9)
Side cleats
1 1/16"
(2.7)
Top cleat
3/4"
(1.9)
5 1/4"
(13.3)
3
(7.6)
9 1/2"
(24.1)
28 1/2" (72.4)
min cutout width
23 1/2"
(59.7) min cutout depth
27 1/4"
(69.2)
31 1/4"
(79.4) min
24 13/16"
(63.0)
cutout depth
24 13/16" (63.0)
cutout depth
23 1/2"
(59.7)
min cutout depth
2 1/2"
(6.4)
Side cleats
depth
29"
(73.7)
Flush inset
height with
1/8" (0.3)
reveal at top,
1/4" (0.6)
reveal at
bottom
11/16" (1.7) Bottom cleat
(Extends full depth of cabinet)
TOP VIEW
STANDARD
INSTALLATION
FLUSH INSET
INSTALLATION
FLUSH INSET INSTALLATION
FRONT VIEW
STANDARD INSTALLATION
FRONT VIEW
STANDARD
INSTALLATION
FLUSH INSET
INSTALLATION
ZET1SHSS
ELEC.
ELEC.
WALL INSTALLATION
A
Based on a user
height of 5' 6"
to 5' 10"
B
Junction box location
(May also be located
in adjacent cabinet.)
C
Platform must be
able to support
220 lbs (99 kg)
D
Cabinet surfaces
must be an
appearance finished
surface for flush
installation.
E
Cleats may be
visible and should
be finished to match
cabinetry.
F
Minimum 31 1/4" from
the top surface of
the countertop to the
top surface of the
wall oven support
platform when
installed beneath a
certified cooktop.
UNDERCOUNTER INSTALLATION
For more details, refer to the installation instructions for this product on Monogram.com.
Dimensions in parentheses are in centimeters unless otherwise noted.
Allow 1/8" (0.3) clearances
from side edges of oven door.
C
C
C
E
B
B
D
A
F